Bosch Appliances ESVVT, GWH 2700 ES LP, GWH 2700 ES NG manual Water connections, Water quality

Models: ESVVT GWH 2700 ES LP GWH 2700 ES NG

1 60
Download 60 pages 19.85 Kb
Page 25
Image 25

Installation instructions

3.9Water connections

Warning: This heater is not approved for preheated water applications.

See chapter 3.11 for approved recirculating application.

Warning:

In applications where inlet water temperature can exceed 140°F (60ºC), a 3-way valve or mixing valve must be installed before the appliance to prevent water exceeding 140°F (60°C) from entering the appliance.

BWhen facing the heater, the ¾” cold connection is on the bottom right and the hot connection is on the bot- tom left. Centrally locating the water heater is recom- mended to keep hot water distribution times even throughout the structure.

COLD

HOT

Fig. 30

BThe use of unions when connecting both water pipes to the inlet and outlet connections is required. This will facilitate any necessary servicing.

BPlastic or PEX type plumbing line materials are not suitable for connecting directly to the water heater.

BAlthough water piping throughout the building may be other than copper, we recommend that copper or suitably rated stainless steel flex line piping be used for the water connections for 1.5’ on either side of the water heater (follow local codes if more stringent).

BNever sweat any piping directly to or beneath the water connections, as damage can occur to the internal water valve from heating of the pipe.

BKeep water inlet and outlet pipes to no less than ¾" (19.05mm) diameter to allow the full flow capacity.

BIf the cold and hot connections to the heater are reversed, the heater will not function. Be certain there are no loose particles or dirt in the piping. Blow out

or flush the lines before connecting to the water heater.

BFull port shutoff valves should be installed on both the cold water supply and hot water outlet lines to facilitate servicing the heater (see Fig. 31).

BFor installation on a private well system with the use of a pressure tank, the lowest pressure range setting recommended is 40-60 psi (2.75 and 4.15 bar).

3.10 Water quality

Water quality can have an impact on appliance longevity and may not be covered under the manufacturer's warranty.

For water analysis data call your local water department, or if on a well, have well water analyzed periodically. If water quality exceeds one or more of the values specified below, Bosch recommends consulting a local water treatment professional for water softening/ conditioning options.

Description

Max. Levels

 

 

 

pH

pH

6.5 - 8.5

 

 

 

TDS (total Dissolved

mg/l or ppm

500

Solids)

 

 

 

 

 

Total hardness

mg/l or ppm

100

(6 grains)

 

 

 

 

 

Aluminum

mg/l or ppm

2.0

 

 

 

Chlorides

mg/l or ppm

250

 

 

 

Copper

mg/l or ppm

1.0

 

 

 

Iron

mg/l or ppm

0.3

 

 

 

Manganese

mg/l or ppm

0.05

 

 

 

Zinc

mg/l or ppm

5.0

 

 

 

Table 13

 

 

6 720 608 542

25

Page 25
Image 25
Bosch Appliances ESVVT, GWH 2700 ES LP, GWH 2700 ES NG manual Water connections, Water quality