Bosch Appliances GWH 2700 ES NG, GWH 2700 ES LP, ESVVT manual Final Readings, 3.0 % 60 ppm

Models: ESVVT GWH 2700 ES LP GWH 2700 ES NG

1 60
Download 60 pages 19.85 Kb
Page 35
Image 35

Maintenance and service

 

 

 

Max. CO

 

 

CO2 range (%)

level

 

 

 

(measured)

 

 

 

 

 

 

Nat. Gas

 

max. input

P1

7.5 % - 8.1 %

< 250 ppm

min. input

P2

2.3 % - 2.6 %

< 60 ppm

 

 

LP Gas

 

max. input

P1

8.7 % - 9.3 %

< 250 ppm

min. input

P2

2.7 % - 3.0 %

< 60 ppm

*Values above are for climate controlled conditions. Inputs such as gas pressure, heating value of the gas, humidity and temperature of combustion air all impact CO

and CO2 values. Changes in these inputs can result in different CO and CO2 values on the same appliance.

Table 17 CO2 & CO target numbers

Final Readings

P2 CO2 Reading:

P1 CO2 Reading:

%CO2

%CO2

Fig. 57 Adjusting P1 CO2 level

6720608158-38.1AL

Fig. 58 Adjusting P2 CO2 level

6 720 608 542

35

Page 35
Image 35