E n g l i s h
ELECTRICAL CONNECTION
Figure 26/Ilus. 26
Figure 27/Ilus. 27
WARNING: ELECTRICAL SHOCK HAZARD - Working on an energized circuit could result in serious injury or death. Only qualified electricians should perform electrical work. Do not attempt any work on the dish- washer electric supply circuit until you are certain the circuit is de- energized.
WARNING: FIRE HAZARD - Improper electrical work can cause fire. Only qualified electricians should perform electrical work.
Grounding Instructions
The dishwasher must be properly grounded before operating. This appliance must be connected to a grounded metal permanent wiring system, or an equipment grounding conductor must be run with the circuit conductors and connected to the equipment grounding terminal or lead on the dishwasher. Make sure that the dishwasher is connected to a suitable ground in compliance with all local codes or, in the absence of a local code, with the NATIONAL ELECTRI- CAL CODE in the United States or the CANADIAN ELECTRIC CODE C22.1- latest edition in Canada as well as any provincial/state or municipal or local codes that apply.
1)Retrieve the strain relief plate, and install a strain relief (not supplied) into the opening on the strain relief plate. NOTE: Orient the strain relief as shown in Figure 26.
2)Pass the electrical supply cable through the strain relief, as shown in Figure 27. Leave 3 - 4 inches of insulated wire extending through the strain relief plate.
3)Tighten the strain relief screws.
4)Slide the strain relief plate into the junction box, and secure it to the junction box with the supplied screw.
(Continued on next page)