24 en Configuring the AutoDome 700 Series

AutoDome 700 Series IP PTZ Camera

 

 

4.11Date/Time

Date format

Select your required date format.

Device date/Device time

If there are multiple devices operating in your system or network, it is important to synchronize their internal clocks. For example, it is only possible to identify and correctly evaluate simultaneous recordings when all units are operating on the same time.

1.Enter the current date. Since the unit time is controlled by the internal clock, there is no need to enter the day of the week – it is added automatically.

2.Enter the current time or click the Sync to PC button to copy your computer's system time to the AutoDome 700 Series.

Device time zone

Select the time zone in which your system is located.

Daylight saving time

The internal clock can switch automatically between normal and daylight saving time (DST). The unit already contains the data for DST switch-overs up to the year 2018. You can use these data or create alternative time saving data if required.

NOTICE!

If you do not create a table, there will be no automatic switching. When changing and clearing individual entries, remember that two entries are usually related to each other and dependent on one another (switching to summer time and back to normal time).

1.First check whether the correct time zone is selected. If it is not correct, select the appropriate time zone for the system, and click the Set button.

2.Click the Details button. A new window will open and you will see the empty table.

3.Select the region or the city that is closest to the system's location from the list field below the table.

4.Click the Generate button to generate data from the database in the unit and enter it into the table.

5.Make changes by clicking an entry in the table. The entry is selected.

6.Clicking the Delete button will remove the entry from the table.

7.Select other values from the list fields below the table to change the entry. Changes are made immediately.

8.If there are empty lines at the bottom of the table, for example after deletions, you can add new data by marking the row and selecting required values from the list fields.

9.Now click the OK button to save and activate the table.

Time server IP address

The AutoDome 700 Series can receive the time signal from a time server using various time server protocols, and then use it to set the internal clock. The unit polls the time signal automatically once every minute.

Enter the IP address of a time server here.

Time server type

Select the protocol that is supported by the selected time server. Preferably, you should select the SNTP server as the protocol. This supports a high level of accuracy and is required for special applications and subsequent function extensions.

Select Time server for a time server that works with the protocol RFC 868.

F.01U.215.777 1.0 2011.07

User Manual

Bosch Security Systems, Inc.

Page 24
Image 24
Bosch Appliances VG5 700 series Date/Time, Date format, Device date/Device time, Device time zone, Daylight saving time