60 en Troubleshooting GuideAutoDome 700 Series IP PTZ Camera

5

Troubleshooting Guide

5.1

VG5 AutoDome Operation and Control

 

 

Problem

Solution

 

 

No video

– Check that the Green LED on the AutoDome CPU board is on. This LED indicates video

 

from the camera.

 

If the Green LED is off, then:

 

– Check that the Red LED on the AutoDome CPU board is slowly blinking. This LED

 

indicates power to the AutoDome power supply board and to the CPU Module.

 

Red LED on AutoDome CPU M0.odule

 

Flash SequenceIndicates:

 

– 5 sec. on / 0.5 sec. off: Normal operation

 

– Steady on: CPU is locked

 

If the Red LED is on steady, then:

Try cycling the AutoDome power off and on.

If the Red LED is off, then:

If using a Bosch Pendant Power Supply Box:

Check that Green LED in Power Supply Box is on. This LED indicates mains power through the transformer.

If the Green LED is off, then:

Turn off the Power.

Check the FX101 fuse for mains power to the Power Supply Box.

If O.K., then:

Check the FX102 fuse for 24 V power to the AutoDome Pendant.

If O.K., then:

If using a non-Bosch power supply:

Check that the mains power to the power supply box is on.

If O.K., then:

Check that there is 24 V output from the transformer.

Check the connector on top of the AutoDome housing for bent pins.

If O.K., then:

Check the integrity of all wires and terminal connections to the AutoDome.

If O.K., then:

If there is power to the AutoDome, then:

Remove the camera and CPU modules from the AutoDome housing and check that the Green LED on the housing power supply board is on.

If the Green LED is off, then:

Check that the fuse on the housing power supply board is good.

F.01U.215.777 1.0 2011.07

User Manual

Bosch Security Systems, Inc.

Page 60
Image 60
Bosch Appliances VG5 700 series user manual Troubleshooting Guide, VG5 AutoDome Operation and Control, If O.K., then