2.3.2Dip Switch Settings

For proper operation, you must set the baud rate, parity, and stop bits of the Printer's interface. On the rear of the Printer, you will find SWITCH 1 (S1), an eight-position dip switch used to set the Printer's communications parameters, (see Table 2-3).

NOTE: SWITCH 1 (S1) is not available with the LCD/Keypad Front Panel Option, (see Section 3.2 when setting the communications parameters for this option).

 

S1-1

S1-2

S1-3

S1-4

S1-5

S1-6

S1-7

S1-8

Baud Rate

 

 

 

 

 

 

 

 

9600

OFF

OFF

OFF

X

X

X

X

X

4800

OFF

OFF

ON

X

X

X

X

X

2400

OFF

ON

OFF

X

X

X

X

X

1200

OFF

ON

ON

X

X

X

X

X

600

ON

OFF

OFF

X

X

X

X

X

300

ON

OFF

ON

X

X

X

X

X

19200

ON

ON

OFF

X

X

X

X

X

TEST/9600

ON

ON

ON

X

X

X

X

X

Word length/Parity

 

 

 

 

 

 

 

 

7-Bit /Even

X

X

X

ON

X

X

X

X

8-Bit /None

X

X

X

OFF

X

X

X

X

Compatibility Mode

 

 

 

 

 

 

 

 

(Form Edge Offset)

 

 

 

 

 

 

 

 

Offset =1.10" (27.9mm)

X

X

X

X

OFF

X

X

X

Offset =2.20" (55.9mm)

X

X

X

X

ON

X

X

X

Present Sensor

 

 

 

 

 

 

 

 

Enable

X

X

X

X

X

ON

X

X

Disable

X

X

X

X

X

OFF

X

X

Control Codes

 

 

 

 

 

 

 

 

Standard

X

X

X

X

X

X

OFF

X

Alternate

X

X

X

X

X

X

ON

X

Cutter Enable

 

 

 

 

 

 

 

 

Disable

X

X

X

X

X

X

X

OFF

Enable

X

X

X

X

X

X

X

ON

Table 2-2 Communications Dip Switch Settings

NOTE: Select the 8-bit word length if you wish to access the foreign language characters from the ASCII Code chart. These characters are available in fonts 1–6 and 9.

_______________________________________________________________________

Getting Started

13

Page 19
Image 19