BASIC FUNCTION INTERNAL BATCH

ENABLE

DISABLE*

BASIC FUNCTION CONVERSION

METRIC

DECIMAL*

BASIC FUNCTION TOF ADJUST

Allows internal label creation with Internal Batch Cartridge

Used to set the Printer's system of measurement

Printer interprets all measurements as metric values

Printer interprets all measurements as decimal values

Selects the point where the label's edge is detected by the sensor

Set start of print from the label's edge. 128 sets the start

of print approximately .3 inches, (7.6 mm) from the label's edge

Advanced Setup

ADVANCED SETUP COUNTERS

ABSOLUTE VALS. RESETTABLE VALS. RESET COUNTERS

ADVANCED SETUP DATE/TIME

SET DAY NAME day hh:mm a dd mon yr

ADVANCED SETUP LABEL OPTIONS

HEAT SETTING

PRINT SPEED

SLEW SPEED

BACKFEED SPEED

ROW ADJUST

COLUMN ADJUST CONT. LABEL LEN

Non-resettable counter (viewed only)

User resettable counter (can keep track of labels)

Resettable values re-start at 0

Allows current date and time to be set

Values: 00 to 30, (*10) (0 = lightest, 30 =darkest)

Values: 2ips to 10ips, (*6) (Print speed/ inches per sec)

Values: 2ips to 10ips, (*7) (Label feed rate/ inches per

sec.

• Values: 2ips to 5ips, (*3.5), (rate the printer backs up label

Vertical position where printing begins, (*0) (shifts up)

Values 0 to 410, (0*)

• Values 0000 to 9999, (*0) (00.00 to 99.99") (label page length)

* represents default setting

_______________________________________________________________________

30

Using Your Printer

Page 36
Image 36
Brady 2024, 2034 manual Advanced Setup, Basic Function TOF Adjust