Routine Maintenance
i Turn the green lock lever (1) clockwise to the lock position.
| 1 |
j Push the drum unit in until it stops. | 5 |
k Close the front cover of the machine.
When you replace the drum unit with a new one, you need to reset the drum counter by completing the following steps:
a Press + or - to choose Machine Info.. Press OK. b Press + or - to choose Reset Parts Life. Press OK. c Press + to choose Drum Unit. Press OK.
d Press + to reset the drum unit counter.
105