CHAPTER 4 OPTIONS
If necessary, set the serial interface parameters as follows:
1.Make sure that the printer is in the
2.Set the serial interface parameters by moving up (on) or down (off) the selectors of the dual
ON
1 2 3 4 5 6 7 8
Fig. 4-2 Setting the Serial Interface Parameters
Table 1: Serial Interface Parameter Settings
Selector | Parameters | On (up) | Off (down) | |
1 | Baud Rate | — | See Table 2. | — |
2 | Baud Rate | — | See Table 2. | — |
3 | Data Length | 7 bits | 8 bits | |
4 | Stop Bit | 2 bits | 1 bit | |
5 | Parity | — | See Table 3. | — |
6 | Parity | — | See Table 3. | — |
7 | Protocol | Xon/Xoff + DTR | DTR only | |
8 | Robust Xon | On |
| Off |
Table 2: Baud Rate Settings |
|
|
| |
|
|
|
| |
Selector 1 | Selector 2 | For | For | |
Off | Off |
| 57600 | 9600 |
On | Off |
| 9600 | 4800 |
Off | On |
| 1200 | 1200 |
On | On |
| 19200 | 19200 |
CHAPTER 4