Symptom

Cause

Remedy

 

 

 

 

If a DHCP/BOOTP server or a

 

 

RARP server resides on the

 

 

network, the IP address is

Create a local environment where the server does

 

automatically issued by the

 

not exist and issue the IP address to the PS-9000. At

 

server. In this case, the IP

 

the same time, make sure that “Obtain an IP address

 

address that was manually set

 

automatically” in the TCP/IP setting is not marked.

 

for the PS-9000 may have

 

 

The print job is

been overwritten by the

 

server.

 

not printed.

 

 

If the PS-9000 and the

 

 

 

 

computer are not in the same

Use the Brother PS-9000 Utility to check whether

 

segment, a subnet mask and

 

the subnet mask and gateway address are correct.

 

gateway address must be set

 

 

 

for the PS-9000.

 

 

 

 

 

 

Check the printer port name of the PS-9000. The

 

 

port name is indicated by “(PTLAN xxxxxx: P-touch

 

 

TCP Port)” after the assigned port name.

Dial-up starts

Depending on the operating

When using PS-9000, cancel the setting for

when printing

system being used, the

automatic dial-up or, if the automatic dial-up setting

automatic dial-up setting may

cannot be cancelled, click [Cancel] in the dialup

is performed.

have been specified.

dialog box to begin printing.

 

If the unit stopped operating

 

An error

because of a tape width error

After the other user’s print job is finished, try printing

occurs during

or no more tape in the cassette

again. Otherwise, use the Web browser to restart

during another user’s print job,

printing.

the PS-9000, and then try printing again.

printing is not possible until

 

the error is cancelled.

 

LPR printing is

With some of the P-touch

With the PT-9200DX, install the printing software

not available

machines, LPR printing is not

for the PS-9000 onto each client, and use it instead

with PS-9000.

available.

of using LPR printing.

The tape width

If PT-9500PC is connected to

 

the PS-9000, the tape width

 

cannot be

 

detection function of P-touch

 

detected by

Editor 4 and Quick Editor does

Manually specify the tape width.

P-touch Editor 4

not operate. (There is no tape

 

or Quick Editor.

width detection function with

 

 

PT-9200DX.)

 

 

 

PS-9000 can be initialized (reset to its factory default

Can the PS-9000

 

settings) by using the Brother PS-9000 Utility.

 

Select PS-9000 in the PS-9000 setting dialog box of

be initialized

 

 

the Brother PS-9000 Utility, and then click

(reset to its fac-

 

[Initialize]. Otherwise, the PS-9000 can be

tory default set-

 

initialized by pressing the push button. For further

tings)?

 

information on how to initialize PS-9000 by pressing

 

 

the push button, refer to “Parts and Functions” in

 

 

chapter 1, “About PS-9000”.

 

 

 

29

Page 30
Image 30
Brother PS-9000 user manual Or Quick Editor, Server. In this case, the IP