Table 12 – PHYSICAL DATA

Table 12 – PHYSICAL DATA

(HEATING)

 

 

Gas Connection

 

580J**12

 

 

 

# of Gas Valves

 

1

 

 

 

 

 

 

 

 

 

 

Nat. gas supply line press (in. w.g.) / (PSIG)

4 --- 13 / 0.18 --- 0.47

 

 

 

 

LP supply line press (in. w.g.) / (PSIG)

11 --- 13 / 0.40 --- 0.47

 

Heat Anticipator setting (Amps)

1st stage

0.14

 

 

 

 

 

 

 

 

 

 

2nd stage

0.14

 

Natural Gas Heat

 

 

 

 

 

 

 

# of stages / # of burners (total)

2

/ 4

 

 

LOW

 

 

Connection Size

3/4” NPT

 

 

 

Rollout switch opens / closes

195

/ 115

 

 

 

 

 

Temperature Rise

25 --- 65

 

 

 

 

# of stages / # of burners (total)

2

/ 5

 

 

 

 

 

 

MED

 

 

Connection Size

3/4” NPT

 

 

 

Rollout switch opens / closes

195

/ 115

 

 

 

 

 

Temperature Rise

30 --- 65

 

 

HIGH

 

# of stages / # of burners (total)

2

/ 5

 

 

 

 

Connection Size

3/4” NPT

 

 

 

Rollout switch opens / closes

195

/ 115

 

 

 

 

 

Temperature Rise

35 --- 70

 

Liquid Propane Heat

 

 

 

 

 

 

 

# of stages / # of burners (total)

2

/ 4

 

 

LOW

 

 

Connection Size

3/4” NPT

 

 

 

Rollout switch opens / closes

195

/ 115

 

 

 

 

 

Temperature Rise

25 --- 65

 

 

 

 

# of stages / # of burners (total)

2

/ 5

 

 

 

 

 

 

MED

 

 

Connection Size

3/4” NPT

 

 

 

Rollout switch opens / closes

195

/ 115

 

 

 

 

 

Temperature Rise

30 --- 65

 

 

HIGH

 

# of stages / # of burners (total)

2

/ 5

 

 

 

 

Connection Size

3/4” NPT

 

 

 

Rollout switch opens / closes

195

/ 115

 

 

 

 

 

Temperature Rise

35 --- 70

 

Low NOx Gas Heat

 

 

 

 

 

 

 

# of stages / # of burners (total)

 

---

 

 

LOW

 

 

Connection Size

 

---

 

 

 

Rollout switch opens / closes

 

---

 

 

 

 

 

Temperature Rise

 

---

 

 

 

 

# of stages / # of burners (total)

 

---

 

 

 

 

 

 

 

MED

 

 

Connection Size

 

---

 

 

 

Rollout switch opens / closes

 

---

 

 

 

 

 

Temperature Rise

 

---

 

 

HIGH

 

# of stages / # of burners (total)

 

---

 

 

 

 

Connection Size

 

---

 

 

 

Rollout switch opens / closes

 

---

 

 

 

 

 

Temperature Rise

 

---

 

 

 

10 - 15 TONS

580J**14

 

580J**16

 

 

 

 

1

 

1

 

4 --- 13 / 0.18 ---

 

5 --- 13 / 0.18 ---

 

0.47

 

0.47

 

11 --- 13 / 0.40 ---

 

11 --- 13 / 0.40 ---

 

0.47

 

0.47

 

0.14

 

0.14

 

0.14

 

0.14

 

2

/ 4

 

2 / 6

 

3/4” NPT

 

3/4” NPT

 

195

/ 115

 

225 / 145

 

25 --- 65

 

20 --- 55

 

2

/ 5

 

2 / 8

 

3/4” NPT

 

3/4” NPT

 

195

/ 115

 

225 / 145

 

30 --- 65

 

25 --- 60

 

2

/ 5

 

2 / 10

 

3/4” NPT

 

3/4” NPT

 

195

/ 115

 

225 / 145

 

35 --- 70

 

35 --- 65

 

2

/ 4

 

2 / 6

 

3/4” NPT

 

3/4” NPT

 

195

/ 115

 

225 / 145

 

25 --- 65

 

20 --- 55

 

2

/ 5

 

2 / 8

 

3/4” NPT

 

3/4” NPT

 

195

/ 115

 

225 / 145

 

30 --- 65

 

25 --- 60

 

2

/ 5

 

2 / 10

 

3/4” NPT

 

3/4” NPT

 

195

/ 115

 

225 / 145

 

35 --- 70

 

35 --- 65

 

 

---

 

 

 

 

---

 

 

 

 

---

 

 

 

 

---

 

 

 

 

---

 

 

 

 

---

 

 

 

 

---

 

 

 

 

---

 

 

 

 

---

 

 

 

 

---

 

 

 

 

---

 

 

 

 

---

 

 

 

580J

17

Page 17
Image 17
Bryant manual Physical Data, Heating, 10 - 15 TONS, 580J**12, 580J**14, 580J**16