Bryant 580J manual Features And Benefits

Models: 580J

1 94
Download 94 pages 40.55 Kb
Page 3
Image 3
FEATURES AND BENEFITS

FEATURES AND BENEFITS

S Single cooling stage models are available from 3 - 10 ton. S Two cooling stage models are available from 7.5 - 15 ton. S SEER up to 13.0.

S EER’s up to 11.1. S IEER’s up to 11.8.

S Up to 28% lighter than similar industry units. Lighter rooftops make easier replacement jobs.

S Utility connections are the same because 3 - 12.5 ton units fit on existing Bryant rooftop curbs. This saves time and money on replacement jobs.

S Standardized components and layout. Standardized components and controls make service and stocking parts easier. S Scroll compressors on all units. This makes service, stocking parts, replacement, and troubleshooting easier.

S Field convertible airflow (3 - 15 ton). Being able to convert a unit from vertical airflow to horizontal makes it easy to overcome job site complications. 15 ton models require a simple supply duct cover to field convert from factory vertical to horizontal.

SEasy-adjust, belt-drive motor available. Bryant provides a factory solution for most points in the fan performance table. S Provisions for bottom or side condensate drain.

S Capable of thru-the-base or thru-the-curb gas line routing. S Single-point gas / electrical connection.

S Sloped, composite drain pan. Sloped, composite drain pan sheds water; and won’t rust.

S Standardized controls & control box layout. Standardized components & controls make stocking parts & service easier. S Tool-less filter access door.

S Clean, easy to use control box. S Color-coded wiring.

S Large, laminated wiring and power wiring drawings which are affixed to unit make troubleshooting easy. S Single, central terminal board for test and wiring connections.

S Fast-access, handled, panels for easy access on normally accessed service panels.

S “No-strip” screw system guides screws into the panel & captures them tightly without stripping the screw, the panel, or the unit.

SExclusive, newly-design indoor refrigerant header for easier maintenance and replacement.

SMechanical cooling (115_F to 40_F or 46_C to 4_C) standard on all models. Winter Start Kit allows cooling operation down to 25_F (-4_C) and Motor Master to -20_F (-29_C).

SHigh efficiency, gas heat with induced-draft flue exhaust design (3 - 15 tons). S Induce draft motor ensures no flue gas can escape into the indoor air stream.

S Bryant designed naturally draining heat exchanger, unlike positive pressure heat exchangers, do not need to be periodically, manually drained. This saves labor and maintenance expense.

S2-in (51mm) disposable filters on all units. S Refrigerant filter-drier on each circuit.

S Each circuit is protected with a high and low pressure switch.

SMany factory-installed options ranging from air management economizers, 2 position dampers, plus convenience outlets, disconnect switch and smoke detectors.

S Standard Parts Warranty: 10 yr. aluminized heat exchanger, 5 yr. compressor, 3 yr. Novation condenser coil, 1 yr. parts.

SFactory-installed Perfect Humidity system on 3 - 12.5 ton models, includes MotorMaster I controller.