LEGEND

LEGEND

Fig. 38 — Typical Wiring Schematic and Fig. 39 — Typical Component Arrangement

AHA

Adjustable Heat Anticipator

IFC

Indoor (Evaporator) Fan Contactor

BKR W/AT

Breaks with Amp Turns

IFCB

Indoor (Evaporator) Fan Circuit

BR

Burner Relay

 

 

Breaker

C

Contactor, Compressor

IFM

Indoor (Evaporator) Fan Motor

CAP

Capacitor

IGC

Integrated Gas Unit Controller

CB

Circuit Breaker

L

Light

CC

Cooling Compensator

LED

Light-Emitting Diode

CH

Crankcase Heater

LOR

Lockout Relay

CLO

Compressor Lockout

LPS

Low-Pressure Switch

CLS

Compressor Lockout Switch

LS

Limit Switch

COMP

Compressor Motor

MAT

Mixed-Air Thermostat

CR

Control Relay

MGV

Main Gas Valve

CT

Current Transformer

NEC

National Electrical Code

DM

Damper Motor

OAT

Outdoor-Air Thermostat

DU

Dummy Terminal

OFC

Outdoor (Condenser) Fan Contactor

EQUIP

Equipment

OFM

Outdoor (Condenser) Fan Motor

FPT

Freeze Protection Thermostat

PL

Plug Assembly

FU

Fuse

QT

Quadruple Terminal

GND

Ground

R

Relay

GVR

Gas Valve Relay

RS

Rollout Switch

HPS

High-Pressure Switch

SN

Sensor

HS

Hall Effect Sensor

SW

Switch

HV

High Voltage

TB

Terminal Block

IDM

Induced-Draft Motor

TRAN

Transformer

NOTES:

1.Compressor and fan motors thermally protected; 3-phase motors protected against pri- mary single-phasing conditions.

2.If any of the original wire furnished must be replaced, it must be replaced with type 90 C wire or its equivalent.

3.Jumpers are omitted when unit is equipped with economizer.

4.IFCB must trip amps is equal to or less than 140% full load amps.

5.On 208/230-v unit, TRAN1 is factory wired to ORN lead for 230-v power supply. If unit is to run on 208-v power supply, TRAN1 must be rewired. Disconnect the BLK wire on TRAN1 and connect wire to 208-v RED wire. Insulate 230-v ORN wire.

6.The CLO locks out the compressor to prevent short cycling on compressor overload and safety devices. Before replacing CLO, check these devices.

7.Number(s) indicates the line location of used contacts. A bracket over (2) numbers sig- nifies a single-pole, double-throw contact. An underlined number signifies a normally closed contact. A plain (no line) number signifies a normally open contact.

Terminal (Marked)

Terminal (Unmarked)

Terminal Block

Splice

Splice (Marked)

Splice (Field Supplied)

Factory Wiring Field Control Wiring Field Power Wiring Accessory or Optional Wiring

To Indicate Common Potential Only, Not To Represent Wiring

Fig. 38 — Typical Wiring Schematic (581A180, 208/230 V Shown)