Bryant A07045, A07044 installation instructions Single-PieceInstallation

Models: A07045 A07044

1 80
Download 80 pages 37.14 Kb
Page 21
Image 21

Single-Piece Installation

The following steps should be followed for the installation of the single-piece configuration.

1.Remove cover from Equipment Control Module by pressing the two tabs on the bottom edge and pulling away. Route wires through large hole in Equipment Control Module. Level Equipment Control Module against wall (for aesthetic value only - Equipment Control Module need not be leveled for proper operation) and mark wall through 2 mounting holes.

2.Drill two 3/16-in. mounting holes in wall where marked. Thermidistat Control may be mounted to a standard junction box if desired. Hole pat- tern on Equipment Control Module matches junction box mounting holes.

3.Secure rear plastic Equipment Control Module to wall with 2 screws and anchors provided. Additional mounting holes are available for more se- cure mounting if needed. Make sure all wires extend through hole in Equipment Control Module.

4.Adjust length and routing of each wire to reach proper connector block and terminal on Equipment Control Module with 1/4-in. extra length. See Fig. 14.

21

Page 21
Image 21
Bryant A07045, A07044 installation instructions Single-PieceInstallation