terminal on the cooling equipment when the dry contact is closed. See Wiring Diagrams for more information.
Default is OF (off).
Option 19 — Dry Contact Configuration
OF — The dry contact is always
ON — The dry contact will operate as a DEHUM relay. This relay is reverse logic. When the humidity level is above the dehumidify setpoint, the dry contact
Default is OF (off).
Option 20 — Outdoor Air Temperature Offset Adjustment
This selection allows the calibration, or deliberate miscalibration of the outdoor air temperature sensor reading. The selection ranges from
Default is 0.
Option 21 — Keypad Lockout (programmable models only)
This selection allows the installer to limit access to the keypad. Selections are OF (off), 1, 2, 3.
OF (off) — The user has full access to the keypad.
1 — The user has access to modify setpoints, time of day.
2 — The user has access to change the setpoints only.