Bryant A07044, A07045 Humidification Selections, To Select Humidification programmable

Models: A07045 A07044

1 80
Download 80 pages 37.14 Kb
Page 44
Image 44

Table 2 – Humidification Selections

SELECTION

FAN DISPLAY

HUMIDIFY SETPOINT

DISPLAY

 

 

 

 

 

 

Normal Humidify

Blank

10

---46

 

 

 

 

Auto Humidify

AUTO

1

---9

 

 

 

Humidify Off

Blank

OF (Off)

 

 

 

 

1.Humidify

In normal humidify, humidifier will be on if there is humidity demand and any heating equipment is on. This will include furnace, heat pump, or auxiliary heat.

2.Auto Humidify

Thermidistat control will automatically adjust the humidity setpoint ac- cording to the outdoor temperature. As the outdoor temperature de- creases, the humidity setpoint also decreases. Settings ranging from 1 to 9, 1 being the lowest and 9 the highest, will be visible to the homeowner. See Fig. 15 for outdoor temperature/indoor humidity relationship in auto humidify mode.

3.Humidify Off

The humidify function can be turned off completely. This does not re- quire changing existing setpoints.

To Select Humidification (programmable)

Press the soft key below the humidify icon to bring up humidity select screen. Humidify options are only available when in Heating mode. When system is in AUTO mode, humidify options are available if the last system operation was a call for heat.

44

Page 44
Image 44
Bryant A07044, A07045 installation instructions Humidification Selections, To Select Humidification programmable