Bryant A07044 Option 11 — Deadband Setting Between Heat & Cool, Option 12 — Smart Recovery

Models: A07045 A07044

1 80
Download 80 pages 37.14 Kb
Page 30
Image 30

Option 11 — Deadband Setting Between Heat & Cool

This option is not available on Heat Only and Cool Only systems. The selection allows the installer to choose how much differential exists between the heating and cooling setpoints. Allowable selections are 1-6.

Default is 2.

Option 12 — Smart Recovery

Smart Recovery OF (off) means setpoints change precisely at setback recovery time. Thirty, 60, or 90 selects the number of minutes recovery starts before programmed recovery time. Recovery takes place smoothly during the selected recovery time, ending at the recovery time and temperature which is programmed. Not available with non-programmable Thermidistat Controls or when Thermidistat Control is configured as non-programmable.

Default is 90.

Option 13 — Room Air Temperature Offset Adjust

The number of _F to be added to the displayed temperature to calibrate or deliberately miscalibrate the measured room temperature ( -5 to +5_F).

Default is 0.

Option 14 — Humidity Display Offset Adjust

The percentage to be added to the displayed humidity to calibrate or deliberately miscalibrate the measured room humidity (-9% to +9% RH).

Default is 0.

Option 15 — Enable Auto Mode

This selection is not available if the Thermidistat Control is configured as Heat Only or Cool Only in Option 1. This allows the homeowner to select auto changeover mode in addition to heat and cool. This allows the Thermidistat

30

Page 30
Image 30
Bryant A07044 Option 11 — Deadband Setting Between Heat & Cool, Option 12 — Smart Recovery, Option 15 — Enable Auto Mode