Bunn 41343 Enable Ads ? No Done Yes, Set Temp Xxx - Done +, Set Ready Xxx - Done +, Enable Ads?

Models: 41343

1 40
Download 40 pages 19.27 Kb
Page 30
Image 30
ENABLE ADS?

PROGRAMMING FUNCTIONS - (cont.)

ENABLE ADS?

This function allows the operator to choose whether or not to display the advertising message that was en- tered into the brewer with an AD CARD. This message will be displayed when the brewer is not in use.

ENABLE ADS ?

NO DONE YES

Procedure to Enable/Disable Ads:

1.Press and hold upper right hidden switch until the display reads UNITS. Release switch. Continue to press and release switch until the display reads ENABLE ADS. The YES or NO will be flashing to indicate the current selection.

2.Press and release the NO to disable this function (no ads will be displayed on the screen), or;

3.Press and release the YES to enable this function (ads will be displayed on screen).

4.When finished, press and release DONE to save the new setting, exit the ENABLE ADS function and advance to the next function screen, SET TEMP. Another alternative is to press and release the ON/OFF switch (either on DUAL brewers) located on the front switch panel to exit the ENABLE ADS function and return to the MAIN SCREEN.

SET TEMP - Range: 185˚F (85˚C) to 205˚F (96˚C) This function allows the operator to set the brew

water temperature in the tank. It also sets the hot water faucet dispense temperature.

SET TEMP: XXX° (-) DONE (+)

Procedure to set brew temperature:

1.Press and hold upper right hidden switch until the display reads UNITS. Release switch. Continue to press and release switch until the display reads

SET TEMP.

2.To adjust the brew temperature, press (-)to de- crease or (+) to increase the brew temperature.

3.When finished, press and release DONE to save the new setting, exit the SET TEMP function and advance to the next function screen, SET READY. Another alternative is to press and release the ON/ OFF switch (either on DUAL brewers) located on the front switch panel to exit the SET TEMP func- tion and return to the MAIN SCREEN.

SET READY - Range: 185˚F (85˚C) to 203˚F (95˚C)

Brew water temperature is factory set at 200F (93.3C) Areas of high altitude will require lowering this tempera- ture to prevent boiling. This chart should be used as a guide when readjusting the brew water temperature.

Altitude

Boiling point

Recommended

 

of water

water temperature

(Feet)

F

C

F

C

 

 

 

 

 

-1000

213.8

101.0

200

93.3

-500

212.9

100.5

200

93.3

0

212.0

100.0

200

93.3

500

211.1

99.5

200

93.3

1000

210.2

99.0

200

93.3

1500

209.3

98.5

200

93.3

2000

208.4

98.0

200

93.3

2500

207.4

97.4

200

93.3

3000

206.5

96.9

199

92.8

3500

205.6

96.4

198

92.2

4000

204.7

95.9

197

91.7

4500

203.8

95.4

196

91.1

5000

202.9

94.9

195

90.6

5500

201.9

94.4

195

90.6

6000

201.0

93.9

194

90.0

6500

200.1

93.4

193

89.4

7000

199.2

92.9

192

88.9

7500

198.3

92.4

191

88.3

8000

197.4

91.9

190

87.8

8500

196.5

91.4

189

87.2

9000

195.5

90.8

188

86.7

9500

194.6

90.3

187

86.1

10000

193.7

89.8

186

85.6

This function allows the operator to set the mini- mum temperature allowable to start a brew cycle. The range can be from 185˚F (85˚C) to within 2˚F (-1.7°C) of the SET TEMP. The water must be at the SET READY temperature or higher for the display to indicate READY TO BREW. If brew lockout is enabled, the brewing pro- cess will not start below this READY temperature.

NOTE: The upper limit for SET READY temperature is 2˚F (-1.7°C) less than the water temperature (SET TEMP) setting.

SET READY: XXX° (-) DONE (+)

Page 30

41343 080108

 

Page 30
Image 30
Bunn 41343 manual Enable Ads ? No Done Yes, Set Temp Xxx - Done +, Set Ready Xxx - Done +, Enable Ads?