PROGRAMMING FUNCTIONS - (cont.)

Procedure to set ready temperature:

1.Press and hold upper right hidden switch until the display reads UNITS. Release switch. Press and release upper right hidden switch until the display reads SET READY.

2.To adjust the ready temperature, press the (-)button to decrease, or (+) to increase the ready temperature.

3.When finished, press and release DONE to save the new setting, exit the SET READY function and advance to the next function screen, REFILL. Another alternative is to press and release either ON/OFF switch located on the front switch panel to exit the SET READY function and return to the

MAIN SCREEN.

REFILL - Range: 20 to 230

This function allows the operator to adjust the sensitivity of the refill circuit. This is mainly a trouble- shooting feature. Water in different geographical loca- tions can have different conductivities. By adjusting the sensitivity of the refill circuit, this will allow the brewer to operate under various water conditions.

XXXREFILL -> XXX (-) DONE (+)

L SPRY OZ/M (DUAL brewers). Another alternative is to press and release the ON/OFF switch (either on DUAL brewers) located on the front switch panel to exit REFILL and return to the MAIN SCREEN.

SPRAY OZ/M

This function allows the operator to view or to enter the actual flow rate coming out of the sprayhead. This is NOT used to change the actual flow rate, but to tell the internal controller how fast the water is flowing. The unit of measure is ounces per minute (Oz/M).

Procedure to set the sensitivity threshold of the refill circuit:

NOTE: Make sure the water in the tank is touching the refill probe.

1. Press and hold upper right hidden switch until the display reads UNITS. Release switch. Press and release upper right hidden switch until the display reads REFILL and shows a number on both sides of the word.

2. To adjust the threshold setting, press (-)to de- crease, or (+) to increase the setting.

NOTE: Always make sure that the number on the right is larger than the number on the left when water is in contact with the refill probe in the tank.

3. When finished, press and release DONE. This saves the new setting and advances to the next function screen:

SPRY OZ/M (SINGLE brewers)

Page 31

41343 080108

 