Bunn 41343 Bypass Oz/M Single Brewers, Bypass Oz/M Dual Brewers, PROGRAMMING FUNCTIONS - cont

Models: 41343

1 40
Download 40 pages 19.27 Kb
Page 33
Image 33
BYPASS OZ/M (SINGLE BREWERS)

PROGRAMMING FUNCTIONS - (cont.)

BYPASS OZ/M (SINGLE BREWERS)

This function allows the operator to view or to enter the actual flow rate coming out of the bypass nozzle. This is NOT used to change the actual flow rate, but to tell the internal controller how fast the water is flowing. The unit of measure is ounces per minute.

Procedure to adjust the flow rate setting:

1.Press and hold the upper right hidden switch until the display reads UNITS. Release the switch, then press and release switch until the display reads BYPAS OZ/M. The number represents what the brewer thinks is the flow rate of the bypass valve in ounces per minute.

2.If the actual flow rate of the bypass valve is known, but is different than the number on the display, use the (-)and (+) to enter the correct flow rate in ounces per minute.

3.When finished, press and release DONE. This saves the new setting and advances to the next function screen, CALIBRATE FLOW. Another alternative is to press the ON/OFF switch located on the front switch panel to exit the BYPASS OZ/M function and return to the MAIN SCREEN.

BYPS OZ/M: XX.X (-) DONE (+)

CALIBRATE FLOW?

NO YES

BYPASS OZ/M (DUAL BREWERS)

This function allows the operator to view or to enter the actual flow rate coming out of the bypass nozzle. This is NOT used to change the actual flow rate, but to tell the internal controller how fast the water is flowing. The unit of measure is ounces per minute.

Procedure to adjust the flow rate setting:

1.Press and hold upper right hidden switch until display reads UNITS. Release switch. Continue to press and release switch until display reads L BYPASS OZ/M. The number represents what the brewer thinks is the flow rate of the bypass valve in ounces per minute.

2.If the actual flow rate of the bypass valve is known, but is different than the number on the display, use the (-)and (+) to enter the correct flow rate in ounces per minute.

3.When finished, press and release the DONE. This saves the new setting and advances to R BYPS OZ/M. When finished setting right side, press and release DONE to advance to next function screen, CALIBRATE FLOW. Another alternative is to press and release either ON/OFF switch located on the front switch panel to exit the BYPASS OZ/M func- tion and return to the MAIN SCREEN.

L BYPS OZ/M: XX.X

(-) DONE (+)

R BYPS OZ/M: XX.X

(-) DONE (+)

CALIBRATE FLOW?

NO YES

Page 33

41343 080108

 

Page 33
Image 33
Bunn 41343 manual Bypass Oz/M Single Brewers, Bypass Oz/M Dual Brewers, PROGRAMMING FUNCTIONS - cont