Bunn 41343 FUNNEL DETECT optional, Procedure to set funnel detect, Funnel Detect, Service Tools

Models: 41343

1 40
Download 40 pages 19.27 Kb
Page 37
Image 37
FUNNEL DETECT (optional)

PROGRAMMING FUNCTIONS - (cont.)

FUNNEL DETECT (optional)

This function allows the operator to prevent the start of a brew cycle if a Smart Funnel is not positioned correctly in the funnel rails.

FUNNEL DETECT ?

NO DONE YES

Procedure to set funnel detect:

1.Press and hold the upper right hidden switch until display reads UNITS. Release the switch. Continue to press and release switch until display reads

FUNNEL DETECT.

2.NO or YES should be flashing to indicate the cur- rent setting.

4.Select YES to prevent brewing if a Smart Funnel is not correctly situated in the rails. If this function is activated and a brew cycle is attempted with the funnel not properly situated, the display will read, FUNNEL NOT IN PLACE, until one is in place.

5.Select NO to allow brewing without a Smart Fun- nel in place. This is selected when brewing with a funnel other than a Smart Funnel (a regular brew funnel).

6.When finished, press and release DONE. This will retain the changes, exit this function screen and advance to the next. Another alternative is to press the ON/OFF switch (either on DUAL brewers) located on the front switch panel to exit the FUN- NEL DETECT and return to the MAIN SCREEN.

SERVICE TOOLS

This function allows the testing of individual com- ponents and the ability to check switches for proper function. This function also tests the funnel sensor coil's frequency (diagnostic tool for troubleshooting purposes only).

Testing individual components (outputs):

This will allow the operator to test the operation of individual components and outputs of the brewer. The components that can be individually tested are as follows:

SINGLE Brewers

Brew Valve

Bypass

Funnel Lock (Optional)

Warmer

Refill Valve

Tank Heaters

Heater Contactor

DUAL Brewers

Left Brew Valve

Left Bypass

Left Funnel Lock

Left Warmer

Right Brew Valve

Right Bypass

Right Funel Lock

Right Warmer

Refill Valve

Tank Heaters

Heater Contactor

Procedure to test components (outputs):

1.Place brew funnels into rails on both sides of brewer.

2.Place a GPR beneath each brew funnel.

3.Press and hold upper right hidden switch until the display reads UNITS. Release switch. Continue pressing and releasing upper right hidden switch until SERVICE TOOLS appears.

4.Press YES to run tests on various components and outputs within the brewer. Pressing NO will exit this function and advance to the next function screen.

5.The display should read TEST OUTPUTS.