TROUBLESHOOTING (cont.) |
|
|
PROBLEM | PROBABLE CAUSE | |
Product overflows container | 1. | Dispense Switch |
| 2. | Dispense Solenoid Valve |
REMEDY
Refer to Service - Dispense Switch for testing procedures. See page 23
Remove the solenoid valve and clear any obstructions. Rebuild or replace the valve if necessary. See page 35
Weak product | 1. Water Temperature | Place an empty container beneath |
|
| the dispense tip. Initiate a dispense |
|
| cycle and check the water tempera- |
|
| ture immediately below the dispense |
|
| tip with a thermometer. Reading |
|
| should be 180°F to 200°F (see ther- |
|
| mostat temperature settings decal |
|
| in USER NOTICES on page 3.) |
2.Whipper Motor
3.Frother
4.Dispense Solenoid Valve
Refer to Service - Whipper Motor for testing procedure. See page 27
Refer to Service - Frother Compo- nents. See page 26
Refer to Service - Dispense Solenoid Valve for test procedures. See page 35
5.Auger Drive
6.Auger Spring
7.Auger Motor
8.Rinse/Run Switch
9.Rinse Timer
10.Relay (120V versions only)
11.Control Board #2 (120V versions only)
Refer to Service - Auger Drive Com- ponents. See page 13 & 15
Refer to Service - Auger Drive Com- ponents. See page 13 & 15
Refer to Service - Auger Drive Com- ponents. See page 13 & 15
Refer to Service - Rinse/Run Switch for test procedures. See page 32
Refer to Operation - Rinse Timer. See Page 5
Refer to Service - Relay for testing procedures. See page 40
Refer to Service - Control Board #2 for testing procedures. See page 22
11 | 35135 012103 |
|