TROUBLESHOOTING (cont.)
PROBLEM
Product will not dispense (cont.)
PROBABLE CAUSE | REMEDY | |
5. | Solenoid Valve (Inlet) | Refer to Service - Solenoid Valve |
|
| (Inlet) for testing procedures. See |
|
| page 37 |
6. | Control Board #1 and Probe | Refer to Service - Control Board and |
|
| Probe for testing procedures. See |
|
| page 20 |
7.Auger Drive
8.Water Strainer
9.Lime
CAUTION - Tank and tank compo- nents should be delimed regularly depending on local water conditions. Excessive mineral
Refer to Service - Auger Drive. See page 13 & 15
Remove the strainer and check for obstructions. Clear or replace.
Inspect the tank assembly for exces- sive lime deposits. Delime as re- quired.
Water is not hot
10. Transformer | Refer to Service - Transformer for | |
|
| testing procedures. See page 41 |
1. | Limit Thermostat | Refer to Service - Limit Thermostat |
CAUTION - Do not eliminate or by- | for testing procedures. See page 31 | |
pass limit thermostat. Use only BOM |
| |
replacement part #29329.1000 |
| |
2. | Control Thermostat | Refer to Service - Control Thermo- |
|
| stat for testing procedures. See page |
|
| 19 |
3. | Tank Heater | Refer to Service - Tank Heater for |
|
| testing procedures. See page 38 |
9 | 35135 012103 |
|