SERVICE (cont.)
AUGER DRIVE COMPONENTS -
Auger Drive Motor (Refer to Fig. 5)
1.Remove all hopper assemblies (20) and set aside for reassembly.
2.Remove the four
3.Remove the four
(16)to the rear of the auger motor mounting panel
(14).
4.Disconnect the wires from the auger motor (16) to be removed.
5.Remove auger motor mounting bracket (15), au- ger motor (16) and dust seal (17) as an assembly.
6.Remove dust seal (17) from auger motor (16).
7.Remove the four
8.Remove auger motor and discard.
9.Using four
(16)on mounting bracket (15).
10.Install dust seal (17) on auger motor shaft.
11.Using four
12.Reconnect the wires to the terminals on the auger motor.
13.Install hopper support plate (19) and all hopper assemblies (20).
14.Refer to Fig. 6 when reconnecting wires.
STATIONS 1 - 5
RED to BRN/WHI from
Control Board #1
RED to WHI/RED from
Control Board #1
RED to WHI/ORN from
Control Board #1
RED to WHI/YEL from
Control Board #2
RED to WHI/BLU from
Control Board #2
BLK to GRN from
Control Board
P1639
FIG. 6 AUGER MOTOR TERMINALS
17 | 35135 012103 |
|