SOLENOID VALVE (DISPENSE) - FMD-4 & FMD-5 (cont.)

Removal and Replacement:

1.Remove the four #8-32 screws securing the side access panel to the housing. Remove panel and set aside.

2.Remove the wires from the solenoid valve.

3.Turn-off the water supply to the dispenser.

4.Using the tank drain tube, drain enough water from the tank so the water level is below the dispense valve mounting hole.

5.Disconnect the water line from the solenoid valve.

6.Remove the #8-32 keps nut securing the solenoid valve bracket to side of the tank. Remove solenoid valve.

7.Install new solenoid valve and o-ring on side of the tank and secure in place with valve mounting bracket and #8-32 keps nut.

8.Push the water line onto the tube on bottom of solenoid valve.

9.Refer to Fig. 32 and reconnect the wires.

10.Reinstall side access panels.

WHIto Main Harness

TAN to Main Harness Station #1

RED to Main Harness Station #2

ORN to Main Harness Station #3

YEL to Main Harness Station #4

BLU to Main Harness Station #5

P1672

FIG. 32 DISPENSE SOLENOID VALVE

TERMINALS