TROUBLESHOOTING (CONT.)
PROBLEM
Dispenser is making unusual noises
Excess dust
Display not lit
PROBABLE CAUSE | REMEDY | |
1. | Plumbing Lines | Plumbing lines should not be rest- |
|
| ing on the counter top. |
2. | Water Supply | (A) The dispenser must be connected |
|
| to a cold water line |
|
| (B) Water pressure to the dispenser |
|
| must not exceed 100 psi (690 kPa). |
|
| Install a regulator if necessary to |
|
| lower the working pressure to ap- |
|
| proximately 50 psi (345 kPa). |
3. | Tank Heater | Remove and clean lime off the tank |
|
| heater. See page 38 |
1. | Fan | Refer to Service - Fan for testing |
|
| procedures. See page 25 |
1. | Lamp | Refer to Service - Lamp, see page 29 |
|
| for lamp replacement. |
2. | Lamp Holder | Refer to Service - Lamp Holder for |
|
| testing procedures. See page 29 |
3. | Starter - Lamp | Refer to Service - Starter for testing |
|
| procedures. See page 30 |
4. | Ballast | Refer to Service - Ballast for testing |
|
| procedures. See page 18 |
12 | 35135 012103 |
|