Bunn FMD-5 service manual Service, Component Access, Contents, AUGER DRIVE COMPONENTS FMD-4

Models: FMD-4 FMD-5

1 45
Download 45 pages 45.11 Kb
Page 13
Image 13
SERVICE

SERVICE

This section provides procedures for testing and replacing various major components used in this dispenser should service become necessary. Refer to Troubleshooting for assistance in determining the cause of any problem.

WARNING - Inspection, testing, and repair of electri- cal equipment should be performed only by qualified service personnel. The dispenser should be un- plugged when servicing, except when electrical tests are required and the test procedure specifically states to plug-in the dispenser.

COMPONENT ACCESS

WARNING - Disconnect the dispenser from the power source before the removal of any panel or the replace- ment of any component.

All components are accessible by opening the door, removal of the door panels, dispenser top cov- ers, hopper(s), hopper support plate, splash guard, splash panel w/drip tray, lower front access panel and rear access cover.

Refer to the contents listing for component loca- tion.

Contents

 

Auger Drive Components (FMD-4)

....................... 13

Auger Drive Components (FMD-5)

....................... 15

Ballast

18

Control Thermostat

19

Control Board

20

Dispense Switch

23

Fan

25

Frother

26

Increase/Decrease Switch

28

Lamp Holder

29

Lamp

29

Lamp Starter and Socket

30

Limit Thermostat

31

Rinse/Run Switch

32

Hot/Cold Switch-Optional

33

Solenoid (Cold Water - Optional)

34

Solenoid (Dispense)

35

Solenoid (Inlet)

37

Tank Heater

38

Tank Heater Switch

39

Tank Heater Relay

40

Transformer

41

Whipper Motor

27

Wiring Diagram

42-45

AUGER DRIVE COMPONENTS FMD-4

J1

J2

J4

J3

J1

J2

J4

J3

P2635

FIG. 1 AUGER DRIVE COMPONENTS

Location

The auger components are located inside the bottom part of the hopper except for the auger drive bracket, spacer and retaining clip, which are located on the outside rear of the hopper base. The auger motor is located on the lower right rear of the motor mounting panel. Refer to Fig. 2 for disassembly and assembly.

Test Procedures - Auger Motor

1.Disconnect the dispenser from the power source.

2.Disconnect the white/red wire and the white wire from the hopper speed control board.

3.Check the voltage across the white/red wire and the white wire with a voltmeter. With the rinse/ run switch in the run (lower) position, connect the dispenser to the power supply. The indica- tion must be :

a)120 volts ac for two wire 120 volt models.

b)120 volts ac for three wire 120/208 volt or 120/240 volt models.

4.Disconnect the dispenser from the power sup- ply.

If voltage is present as described, proceed to #5.

If voltage is not present as described, refer to the wir- ing diagram and check the dispenser wiring harness.

13

35135 012103

 

Page 13
Image 13
Bunn FMD-5 service manual Service, Component Access, Contents, AUGER DRIVE COMPONENTS FMD-4