PROGRAMMING THE BREWER (cont.)

PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)

* SET TEMP - ICB (MASTER TEMP - ITCB)

This function allows the operator to adjust the brew water temperature in the tank. This also sets the hot water faucet dispense temperature.

Procedure for setting the Set Temp

Range: 185° to 205° F (85° - 96° C)

1.Press and hold the right hidden button until the display reads SET LANGUAGE. Press the right hidden button until the display reads SET TEMP.

2.Using (-)and (+), adjust the brew and faucet tem- perature.

3.When finished, press and release DONE to save the new setting and to advance to the next function screen, READY DEGREE. Press ENABLE BREW ON/ OFF switch to exit programming and return to the

MAIN SCREEN.

* READY DEGREE

This function allows the operator to set the minimum temperature allowable to start a brew cycle. The range can be from 2° to 20° F below the set temperature. The water must be at the READY temperature or higher for the display to indicate READY TO BREW. If brew lockout is enabled, the brewing process will not start below this READY temperature.

Procedure to set ready temperature

Range: 2° to 20° F (2° to 10° C) below set temp

1.Press and hold the right hidden button until the dis- play reads SET LANGUAGE. Press the right hidden button until the display reads READY DEGREE.

2.Using (-)and (+), adjust the ready temperature.

3.When finished, select DONE to save the new setting and to advance to the next screen, ENABLE ADS. Press ENABLE BREW ON/OFF switch to exit.

* ENABLE ADS

This function allows the operator to choose whether or not to display an advertising message. An ad can be saved to the brewer by either writing the ad using the programming commands, or by entering the ad into the brewer using an AD CARD. This message will be displayed when the brewer is not in use.

Procedure to Enable/Disable Ads:

1.Press and hold the right hidden button until the display reads SET LANGUAGE. Press the right hid- den button until the display reads ENABLE ADS. The YES or NO will be flashing to indicate the current selection.

2.Select NO to disable this function, or:

3.Select YES to enable this function.

4.When finished, select DONE to save the new setting and advance to the next function screen.

5.If NO was selected, the display should now read ENABLE SANITATION. To exit programming and return to the MAIN SCREEN, press ENABLE BREW ON/OFF switch.

6.If YES was selected, the display should now read NEW AD?. This screen allows the operator to select between using an ad card to read in a new ad, or writing an ad through the control panel.

Procedure to WRITE an Ad:

NOTE: Writing and saving a new ad will erase any previously saved ad in the brewer’s memory.

7.From the NEW AD? screen, select WRITE.

8.The display should now read 2 LINES 16 CHARS AVAILABLE, and then SCROL THRU ALPHA, NEXT -> NEXT LETTER, and then WRITE TOP LINE?. The ad can be up to 32 characters long, 16 per line. The ad will be written in two steps, first the top line, then the bottom line.

9.To write the top line of a new ad, select YES. To skip the top line and only write a bottom line, select NO and proceed to step 13.

10.The display will now read A with a flashing cursor below it. Press the SCROLL button to scroll through the alphabet and available characters. When the de- sired character is shown on the display, select NEXT to move to the next character in the top line.

11.Repeat step 10 until the top line is complete.