TROUBLESHOOTING (cont.) |
|
|
|
|
PROBLEM |
| PROBABLE CAUSE |
| REMEDY |
Automatic refill will not operate |
| 1. No water |
| Check plumbing and |
or display shows FILL TIME TOO |
|
|
| valves |
LONG |
| 2. Refill probe or Sensitivity set- |
| Remove the strainer and check for |
|
|
| ||
|
| ting |
| obstructions. Clear or replace. |
|
| 3. Refill valve |
| Check the sensitivity setting. Refer |
|
|
|
| to the REFILL function on page |
|
|
|
| 40. If the left three digit number |
|
|
|
| is less than the right number, the |
|
|
|
| machine “thinks” it is full and the |
|
|
|
| refill valve should be off. If the left |
|
|
|
| number is larger than the right, then |
|
|
|
| the refill valve will automatically be |
|
|
|
| turned on to fill the tank. The right |
|
|
|
| number is the threshold setting and |
|
|
|
| can be adjusted to compensate for |
|
|
|
| extreme water conditions: very pure, |
|
|
|
| low conductance water requires a |
|
|
|
| higher setting, while high mineral |
|
|
|
| content, high conductance water |
|
|
|
| requires a lower setting. Note that |
|
|
|
| the left number changes from a high |
|
|
|
| value when water is NOT touching |
|
|
|
| the refill probe to a low valve when |
|
|
|
| water IS touching the probe. For |
|
|
|
| best operation, the right number |
|
|
|
| should be set to a value midway |
|
|
|
| between these low and high num- |
|
|
|
| bers. Before changing the setting, |
|
|
|
| confirm that the refill probe is free |
|
|
|
| of scale buildup and the connection |
|
|
|
| to it is secure. Test the refill valve. |
|
|
|
| Refer to the test outputs procedures |
|
|
|
| on page 48. |
Page 32 | 41581.2 091609 |
|