PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)
9.If both batch sizes are correct, press YES. This will advance to the DILUTE OZ (ITCB) or BYPASS % (ICB)
10.Using
11.When finished, press the other batch size and repeat step #10.
12.When finished setting both batch sizes, press and release DONE. The display should read 2 BATCHES
DONE?
13.If both batch sizes are not correct, select NO to return to the BYPASS % function (ICB) or DILUTE OZ function (ITCB) and repeat steps
14.If both batch sizes are correct, press YES. This will advance to the DILUTE DELY function (ITCB) or SET PULSE BREW function (ICB) jump to step # 21.
15.(ITCB ONLY) Press and release YES. The display should now read DILUTE DELY: and a batch light will be blinking. Press and release the batch size to be modified.
16.Using
17.When finished, press the other batch size and repeat step # 16.
18.When finished setting both batch sizes, press and release DONE. The display should read 2 BATCHES
DONE?
19.If both batch sizes are not correct, press and release NO to return to the DILUTE DELY setup screen and repeat steps 16 - 18.
20.If both batch sizes are correct, press YES. The display should now read SET PULSE BREW.
21.To set PULSE BREW press YES. The display should now read SELECTMETHOD. To set the EASY method, continue to step # 22. To set by MANUAL method, jump to step # 28.
INITIAL SPRAY | ON- | ON- |
| ON- |
TIME | TIME |
| TIME ALTERNATES UNTIL | |
|
| |||
|
|
|
| BREW CYCLE IS |
OFF- | OFF- |
| OFF- | COMPLETED |
|
| |||
TIME | TIME |
| TIME |
|
INITIAL SPRAY |
|
|
|
|
REMAINING ON |
|
|
| |
|
|
|
| |
|
|
|
|
Setting Pulse Brew – EASY Pulse Brew
Range: Minimum: will adjust to the minimum time required to brew that batch using the set brew volumes and flow rate for the sprayhead. Maximum – will adjust depending on settings and will always be minimum time
+3 minutes. The brewer will automatically calculate what the 1ST ON TIME, OFF TIMES, and LAST ON TIME will be using THE INITIAL ON TIME, plus a 7 pulse routine.
22.Select EASY. With EASY flashing, select NEXT.
23.The display should now read BREW TIME: and a batch light will be blinking. Select the batch size to be modified.
24.Using
25.When finished, press the other batch size and repeat step # 24.
26.When finished setting both batch sizes, press DONE. The display will show the pulse settings to accommodate the brew time entered. Press and release each batch size to display the settings for that batch. After a delay, the display should read 2
BATCHES DONE?
27.If both batch sizes are not correct, press NO to return to the BREW TIME setup screen and repeat steps
Setting Pulse Brew/PreInfusion – MANUAL
28.Select MANUAL. With MANUAL flashing, select NEXT.
29.The display should now read, 1st ON TIME and a batch light will be blinking. Select the batch size to be modified.
30.Using
31.When finished, press the other batch size and repeat
step # 30.
NOTE: To disable pulse brew, set 1ST ON TIME to OFF. Brewer will automatically pulse on tea recipes with a brew volume greater than 86.0 oz.
32.When finished setting both batch sizes, press DONE.
33.The display should now read OFF TIME. Adjust the OFF TIME using
(cont.)
Page 14 | 41581.2 091609 |
|