PROGRAMMING THE BREWER (cont.)
PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)
* ASSET NUMBER
This function allows the operator to enter the machine's asset number. This can be useful for tracking the usage or service of an individual machine within a group.
Procedure to enter the asset number:
1.Press and hold the right hidden switch until the display reads SET LANGUAGE. Press and release the right hidden switch until the display readsENTER
ASSET #?
2.Select YES. The display will now read
ANXXXXXX.
3.Scroll down
4.When finished, press and release DONE. The display
will now read SERVICE #. To exit programming and return to the MAIN SCREEN, press ENABLE BREW ON/OFF switch.
NOTE: To view the Asset Number, press and hold the left hidden switch until the display reads ASSET NUMBER. After releasing the switch, the display will read SERIAL NUMBER then the software version.
* SERVICE NUMBER
This function allows the operator to enter in the tele- phone number to call if service is needed. The service number will be displayed anytime there is a fault mes- sage displayed.
Procedure to enter the service number:
1.Press and hold the right hidden switch until the display reads SET LANGUAGE. Press and release the right hidden switch until the display reads
ENTER SERVICE #?
2.Press and release YES. The display will now read SCROL THRU #'S NEXT
3.Press the SCROL button to scroll through the num- bers. When the desired number is shown, press and release NEXT to move to the next digit in the phone number.
4.Repeat Step 3 until the entire number is entered.
5.Press and release DONE. The display will now read
SERVICE TOOLS?
* SERVICE TOOLS
(FOR AUTHORIZED SERVICE PERSONNEL ONLY) This function allows the testing of individual components and the ability to check switches for proper function. This function also tests the funnel sensor coil’s frequency (diagnostic tool for troubleshooting purposes only). Refer to Service Manual for in depth procedures.
Test Outputs:
The following components can be individually tested: (L/R) Brew Valve(s)
(L/R) Bypass Valve(s) ICB(TWIN)
(L/R) Dilution Valve(s) ITB/ITCB (w/Dual Dilution) Refill Valve
Tank Heater Relay
Tank Heater Triac
L/R Funnel Lock (Optional) Sweetener Solenoid (Optional)
Test Switches:
The following components can be individually tested: Membrane Switches
Test Frequency: (NOT AVAILABLE ON ITB)
The following components can be individually tested: L/R Smart Funnel read coils.
* FACTORY DEFAULTS
This function allows the operator to erase ALL of the previously entered recipes and ad messages.
Procedure to set factory defaults:
1.Press and hold the right hidden switch until the display reads SET LANGUAGE. Press and release the right hidden switch until the display reads FAC-
TORY DEFAULTS.
2.Press YES to restore defaults. The display will read WILL REPLACE ALL BREW SETTINGS followed with
ARE YOU SURE?
3.Selecting NO, will exit without resetting. Select YES to load the defaults. After factory defaults have been restored, the display will return to the MAIN SCREEN. The factory default values will have replaced ALL previously entered values. It will NOT reset the life brew counter. If factory defaults are restored, it will be necessary to recalibrate the flow rates.