Figure 36: Burner Adapter Plate Options

Power Flame (‘C’ Series) Burner Adapter Plate

Boiler Model

Part No.

I.D.

‘A’

‘B’

 

 

No.

 

 

MPC4 thru MPC7

602263401

40

7-1/2

10-1/4

MPC8 thru MPC14

602263411

41

9

12

MPC15 thru MPC18

602263421

42

10-3/8

14-1/8

Power Flame (‘JR’ Series) Burner Adapter Plate

Boiler Model

Part No.

I.D.

‘A’

‘B’

 

 

No.

 

 

MPC4 thru MPC7

602263451

45

6-3/8

10-1/4

MPC8 thru MPC11

602263461

46

8-3/8

11-11/16

Beckett (‘CF’ Series) Burner Adapter Plate

Boiler Model

Part No.

I.D.

‘A’

‘B’

 

 

No.

 

 

MPC4 thru MPC7

602263001

00

6-3/4

10

MPC8 thru MPC15

602263011

01

8-1/4

10

MPC16 thru MPC18

602263021

02

10-1/4

11

Beckett (‘CG’ Series) Burner Adapter Plate

 

Boiler Model

Part No.

I.D.

‘A’

‘B’

 

 

No.

 

 

MPC4 and MPC5

602263031

03

5

10

MPC6 and MPC7

602263041

04

6

10

MPC8 thru MPC11

602263071

07

7-1/4

10

MPC12 thru MPC18

602263081

08

8-1/8

11

1.In most cases the burner adapter plate carton for the specified burner will be provided by Burnham.

2.If adapter is provided by Burnham, open carton and remove contents. Apply four (4) small dabs of silastic on rear surface of adapter plate to temporarily hold gasket in place. Hold adapter plate in position against burner swing door, align holes and secure with four (4) 3/8” lock washers and 3/8” - 16 x 7/8” lg. cap screws.

3.If adapter is furnished with burner, follow manufacturer’s instructions using gasket material and hardware provided with burner.

4.USE A HOLE SAW OR KNIFE TO CUT BURNER SWING DOOR INSULATION TO MATCH HOLE SIZE ON BURNER ADAPTER PLATE. After cutting, remove any and all loose pieces of insulation which may become lodged or interfere with the head of the burner air tube after insertion.

5.Secure burner to adapter plate with four (4) ½” lock washers and four (4) ½” - 13 hex nuts provided.

CAUTION

Failure to properly fill all gaps between the insulation and burner blast tube may result in damage to the burner.

6.Confirm that hole in insulation fits snugly around burner blast tube. If hole is oversized, open burner swing door (with burner attached) to access burner blast tube. Use additional fiberglass rope gasket provided with burner to fill in any space between insulation and blast tube. If additional rope gasket is not provided with the burner, use 3/8” fiberglass rope rated for 2300°F (provided by others).