Figure 16: Secure Brackets to Horizontal Channel

5.Add front/center section mounting hardware to all but one (1) horizontal support channel assembly.

Lay channel assembly on floor with brackets facing up, see Figure 17a. Install hardware as shown with two (2) washers and two (2) 1/2” lg. spacers between bracket legs and one (1) washer and one (1) hex nut on each end of 3/8” -16 x 3-1/4” lg. rod, see assembled end view in Figure 17a. Repeat for all brackets.

6.Add rear section mounting hardware to remaining horizontal support channel assembly. Lay channel assembly on floor with brackets facing up, see

Figure 17b. Install hardware as shown with one

(1) 1-3/4” lg. spacer between bracket legs, one (1) washer and one (1) hex nut on one end of 3/8” -16 x 13-3/8” lg. threaded rod, with one (1) washer,

Table VIII: Frame/Bracket Mounting Locations

one (1) 2-5/8” lg. spacer, two (2) washers and one

(1) hex nut on the opposite end of rod. Repeat for second bracket, refer to assembled end view in Figure 17b.

7.Mount front/center horizontal channel assembly(lies) to appropriate casting(s) on block assembly as outlined in Table VIII. Position threaded rods on channel assemblies over slotted lugs on casting as shown in Figure 18a. Spread inside washers until rod drops to bottom of slot as shown in Figure 18a, Detail ‘A’. Hand tighten nuts, make sure washers engage casting below washer retaining lugs, see Detail B. Repeat for all remaining bracket attachment points.

8.Mount rear horizontal channel assembly to rear section and adjacent center section as shown in Figure 18b. Position assembly behind supply manifold, spread washers and lower threaded rod into slotted openings on both castings as shown in Figure 18b, Detail A. Hand tighten nuts, make sure washers engage casting below washer retaining lugs as shown in Detail B. Repeat for opposite side.

9.Wrench tighten hex nuts on all channel assemblies making sure rods are fully seated in slotted openings.

10.Locate and install lower front/center section brackets to casting legs. Brackets are universal and can be used on either side of block assembly. Refer to Table VIII for appropriate casting leg to be used for bracket attachment. Brackets mount to rear surface of leg with offset toward the rear as shown in Figure 19. Hold bracket at a 45° angle while engaging upper slot over threaded tie rod, rotate bracket around rod until lower slot is aligned with lower hole in casting leg. Insert 5/8 -11 x 2” lg. bolt with washer through cast hole in leg and slot in bracket.

Boiler Size

 

Front

f

Block Assembly

g

Rear

 

 

 

 

 

 

 

 

Frame 1

Frame 2

Frame 3

Frame 4

Frame 5

 

 

 

 

 

 

 

 

4 Section

Front Section

Rear Section

-----

 

-----

-----

 

 

 

 

 

 

 

5 Section

Front Section

Rear Section

-----

 

-----

-----

 

 

 

 

 

 

 

6 Section

Front Section

Rear Section

-----

 

-----

-----

 

 

 

 

 

 

 

7 Section

Front Section

Section 4

Rear Section

 

-----

-----

 

 

 

 

 

 

 

8 Section

Front Section

Section 5

Rear Section

 

-----

-----

 

 

 

 

 

 

 

9 Section

Front Section

Section 5

Rear Section

 

-----

-----

 

 

 

 

 

 

 

10 Section

Front Section

Section 6

Rear Section

 

-----

-----

 

 

 

 

 

 

 

11 Section

Front Section

Section 6

Rear Section

 

-----

-----

12 Section

Front Section

Section 5

Section 9

Rear Section

-----

13 Section

Front Section

Section 5

Section 9

Rear Section

-----

14 Section

Front Section

Section 5

Section 10

Rear Section

-----

15 Section

Front Section

Section 6

Section 11

Rear Section

-----

16 Section

Front Section

Section 6

Section 11

Rear Section

-----

17 Section

Front Section

Section 5

Section 9

Section 13

Rear Section

18 Section

Front Section

Section 5

Section 10

Section 14

Rear Section

31

Page 31
Image 31
Burnham FM01FD00B manual Secure Brackets to Horizontal Channel, Table Viii Frame/Bracket Mounting Locations

FM01FD00B specifications

The Burnham FM01FD00B is a remarkable heating solution that combines efficiency, reliability, and advanced technology to meet the demands of modern homes and commercial spaces. Standing out in the crowded market of heating systems, the FM01FD00B is designed for those who prioritize both performance and energy savings.

One of the most significant features of the Burnham FM01FD00B is its advanced combustion technology. The system utilizes a high-efficiency burner that maximizes fuel usage, resulting in lower operating costs and reduced environmental impact. The unit is engineered to provide consistent heat distribution, ensuring that every corner of a room reaches a comfortable temperature quickly and effectively.

In addition to its efficient burning capabilities, the FM01FD00B is compatible with multiple heating mediums, allowing it to adapt to various fuel types, including natural gas and propane. This versatility makes it an excellent choice for homeowners looking for flexible heating options that can cater to their specific needs.

The FM01FD00B also comes equipped with a state-of-the-art control system that offers precise temperature management. Users can easily program their desired heating schedule, ensuring optimal comfort at all times. The intuitive interface allows for easy adjustments, making it simple to maintain a cozy environment whether at home or away.

Another key characteristic is the unit's robust construction. Built with high-quality materials, the Burnham FM01FD00B is designed to withstand harsh conditions and provide lasting performance. The durable exterior is resistant to corrosion, further enhancing its longevity and reliability.

Moreover, the system features built-in safety mechanisms that protect against overheating and other potential hazards, ensuring peace of mind for users. This focus on safety extends to its low emissions, making it an eco-friendly choice for those looking to reduce their carbon footprint.

In conclusion, the Burnham FM01FD00B is a high-efficiency heating solution that excels in performance, adaptability, and safety. Its advanced technologies, robust construction, and user-friendly features make it an ideal choice for anyone seeking a dependable and efficient heating system for their home or business. Whether you prioritize energy savings, reliability, or comfort, the FM01FD00B stands out as a top contender in the heating market.