Section 3 | Optipay™CC | DESIGN |
If at any time another combination of tube coins is required, the appropriate cassette can be ordered from the JCM and simply exchanged in the assembly (See Figure
Figure 3-6 Tube Cassette Removal/Replacement
Payout Module
Vending change is done by two motors installed at the bottom of the Payout Set (See Figure
The left side motor is responsible for vending the left “Tube L (5)” and middle left “Tube ML (4)” tube coins, and the right side motor is responsible for vending the right “Tube R (2)” and middle right “Tube MR (3)” tube coins.
Filling Level Sensors
The capacity of each tube is monitored by four independent sensors viewing the number of it’s related coins:
•An empty sensor is positioned at the height of 8 to 10 collected coins
•A 50% sensor approximately half way up
•A 75% sensor near the top, and
•A full sensor is positioned at the top rim of each tube.
In order for the tube counters to function without fault when the change tubes are filled by inserting coins through the Coin Changer, or when the tubes are filled by removing the four Tube Cassette, the filling level sensors must check the tube counter’s status after every coin acceptance and coin vend.
If the number of coins does not correspond with the measured tube capacity level, the tube count will be corrected depending on the respective tubes coin thickness.
If a tubes "full" sensor displays the message "tube full", all further coins for this tube will be auto- matically directed to the Cash Box. Only when coins have been vended again from this tube, will more coins be allowed into the tube.
MDB Vending Machine Cable
The MDB Interface Connecting Cable (See Figure
5900335 © 2005