A-66 Coin Changer

S e c t i o n 5

5 INSTALLATION

This section provides a installation instructions for the Optipay™ CC A-66 Coin Changer.The A-66 Coin Changer is either:

Energized within a Vending Machine, or

Connected to a JCM Test Station using WinMDB© software for test purposes or

Connected to one of the following JCM configuration tools for set up purposes:

A PC programming station containing WinEMP© software

A Palm Pilot® handheld (containing

installed PalmA66® and/or PalmEMP® software).

This section describes how to connect the Coin Changer to a Vending Machine. For details on con- necting the service tools, see section 11 "Config- uration".

To avoid damage to the equipment, please make sure that you check the following before installation:

check that the Coin Changer’s MDB connecting cable is suitable for the Vending Machine interface.

check that the Coin Changer’s power supply is the same as the nominal voltage stated on its product label.

The following steps describe how to install the Coin Changer into a Vending Machine:

1.Disconnect the Vending Machine’s main AC power plug.

2.Unlock (See Figure 5-2 [1]), pull out [2] and remove the Coin Validator from the Coin Changer assembly by carefully lifting the left and right side catches and gently pulling forward as indicated by the arrows illustrated in Figure 5-1.

3.Hang the A-66 in the Vending Machine using the three mounting holes located on the back wall of the Coin Validator. Two holes are

Figure 5-1Coin Validator Removal

Upper Mounting Holes

3

Pull

Lift up

 

Out

 

 

1

 

2

 

 

 

 

 

 

4 Another hole

at bottom

Figure 5-2Coin Changer mounting hole locations

located at the top (See Figure 5-2 [3]) and one is located at the bottom [4] (not shown).

Ensure that the Coin Validator assembly remains safely connected to the Coin Changer by the flat 40-wire ribbon cable.

4.Tightly secure the Coin Changer's housing to the Vending Machine.

5.Replace the Coin Validator back into the Coin Changer and engage.

Ensure that an air space exists between the Vending Machine’s return lever and that of the Coin Changer when closing.

5900335 © 2005 JCM-American Corporation

5 - 1