C. Crane A-66 manual Diagnosis Using a Palm Pilot Set- ting Module, Display Meaning Trouble

Models: A-66

1 56
Download 56 pages 31.91 Kb
Page 50
Image 50

Appendix A

Optipay™CC

TROUBLE SHOOTING

Table A-1 LED Indicator Meanings (Continued)

LED

Meaning

Trouble

 

 

 

 

 

 

Yellow

Coins stuck in

Remove tube cassette

Flashes

vend area or

and any jammed coins,

Twice

motor failure

then vend one coin from

 

 

each tube using the

 

 

inventory keys or Ser-

 

 

vice case

Yellow

Coin changer

Check Vending

Flashes

inhibited

Machine (possibly

3 times

by Vending

empty or defective)

 

Machine

 

Red

Fault in Coin

Remove jammed coins

Flashes

Validator

by pressing the return

once

 

lever on the Coin Valida-

 

 

tor or Service case, Coin

 

 

Validator may have to be

 

 

exchanged

Red

Fault in Coin

Service case, Coin

Flashes

Validator

Validator may have to be

twice

 

exchanged

Red

Vending

Check Vending

Flashes

Machine no

Machine control or

3 times

longer com-

connecting cable

 

municates

 

 

with Coin

 

 

Changer (has

 

 

sent no com-

 

 

mand in 2

 

 

secs.)

 

Diagnosis Using a Palm Pilot® Set- ting Module

If a Coin Changer fault occurs, the Palm Pilot® Set- ting Module displays the appropriate status or error message as soon as you connect it to the RJ-45 interface jack on the Coin Changer’s front panel (see chapter 11 "Configuration"). Depending on the operating mode or fault, three status or fault messages are displayed as follows:

INFO messages: used in general only for information about particular operating states

AN/AB messages: indicate where a coin was accepted (AN) or why a coin was rejected (AB)

FE messages: indicate why the Coin Changer no longer functions (Table A-2).

Table A-2 Display Indicators

Display

Meaning

Trouble

 

 

 

 

 

 

INFO

Return Lever

No error or, check the

INFO -01

pressed or a

return mechanism in

 

switch in Coin

Vending Machine, or

 

Validator defec-

Service case

 

tive

 

Table A-2 Display Indicators (Continued)

Display

Meaning

Trouble

 

 

 

 

 

 

InFo-09

String sensor

Coin on string

 

active

recognized (no error),

 

 

or

 

 

check sensor

 

 

(Service case)

InFo-09A

Tube coins are

No error.

 

delivered to the

This function can be

 

cash-box after

deactivated however,

 

a recognized

using PRO 04 02

 

string manipu-

 

 

lation

 

InFo-80

Coin Changer

Check Vending

 

inhibited by

Machine (possibly

 

Vending

empty or defective)

 

Machine

 

AN

Accepted coin

No error

An X YY

 

will be sorted

 

 

into:

 

 

X = 0 cash-box

 

 

X = 1 left tube

 

 

X = 2 middle

 

 

left tube

 

 

X = 3 middle

 

 

right tube

 

 

X = 4 right tube

 

An X YY

Inserted coins

 

accepted in the

 

 

coin channel

 

 

YY = 01–16

 

 

(Channel No.)

 

AB

Measured

If necessary, widen

Ab-01

 

inserted coin

acceptance band limit

 

values are out-

using with WinEMP© or

 

side the accep-

PalmEMP©

 

tance band limit

 

Ab-02

Inserted coin

Enable coin channel

 

inhibited by the

using DIP Switch Block

 

Coin Changer

or Palm Setting Module

 

 

with WinEMP© or Palm

 

 

Pilot® with PalmA66©

Ab-03

Inserted coin

Remove coins or for-

 

has not passed

eign objects by press-

 

through mea-

ing the return lever on

 

surement sec-

the Coin Validator, or

 

tion in the

check measurement by

 

appropriate

air-core coil or CP2

 

amount of time

level (Service case)

Ab-04

Inserted coin

Insert coin again more

 

was not recog-

slowly

 

nized

 

Ab-05

CP3 or CP4

Insert coin more slowly,

 

sensor active

or inserted coin not on

 

 

string or check sensors

 

 

(Service case)

5900335 © 2005 JCM-American Corporation

A - 2

Page 50
Image 50
C. Crane A-66 manual Diagnosis Using a Palm Pilot Set- ting Module, Display Meaning Trouble