Unpacking and Installing Your ELS100-16TX

2.3 INSTALLING THE ELS100-16TX

Rack-Mounting an ELS100-16TX

Table 2-3 describes some general considerations you should be aware of before mounting an ELS100-16TX in a rack assembly.

Table 2-3. General Considerations for Mounting an ELS100-16TX

Consideration

Discussion

 

 

Temperature

Since the temperature within a rack assembly

 

may be higher than the ambient room

 

temperature, make sure the rack environment

 

temperature is within the Operating

 

Temperature range specified in Appendix A.

 

 

Air Flow

Make sure there is at least 2 inches (or more)

 

on both sides of the ELS100-16TX to allow for

 

adequate air flow.

 

 

Mechanical Loading

Do not place equipment on top of a rack-

 

mounted ELS100-16TX.

 

 

Circuit Overloading

Make sure the power supply circuit to the

 

rack assembly is not overloaded.

 

 

Grounding

Rack-mounted equipment should be

(Earthing)

grounded. In addition to the direct

 

connections to the main power supplies, make

 

sure all the other supply connections are also

 

grounded.

 

 

The ELS100-16TX can be rack-mounted in a standard 19-inch equipment cabinet. To mount the ELS100-16TX in a rack assembly, apply the following steps:

1.Attach the rackmount brackets to either side of the ELS100- 16TX chassis, as shown in Figure 2-3.