3.15.3 Disabling the ILMI Status

The Signalling Screen

NOTE

In [Enabled] mode, the user is allowed to force the HSIM-A6DP to use a desired version of UNI, rather than having the HSIM-A6DP use the version of UNI that the ATM switch to which it is connected is currently using.

3.Use the arrow keys to highlight the UNI Version field.

4.Press the SPACE bar to toggle between the options until the desired version of UNI displays.

5.Use the arrow keys to highlight the SAVE command located at the bottom of the screen and press ENTER. The changes are saved to memory.

3.15.3 Disabling the ILMI Status

To change the ILMI status from the default state of [Auto Configure Enabled] perform the following steps:

1.Use the arrow keys to highlight the ILMI Status field.

2.Press the SPACE bar until the option [disabled] displays.

Before completing the following step, ensure that this caution is

!fully understood. By disabling the ILMI, ALL SVCs currently

CAUTION

configured on the HSIM-A6DP will be lost.

 

3.Use the arrow keys to highlight the SAVE command located at the bottom of the screen and press ENTER. The ILMI has been disabled.