3.20THE ADD/DELETE ENTRY SCREEN

Chapter 3: Local Management

3.20THE ADD/DELETE ENTRY SCREEN

To access the Add/Delete Entry screen from the ATM Connection Setup screen perform the following steps:

1.Use the arrow keys to highlight the ADD/DELETE command at the bottom of the ATM Connection Setup screen.

2.Press ENTER, the Add/Delete Entry screen, Figure 3-19, displays.

 

 

 

6E132-25 LOCAL MANAGEMENT

 

 

 

INTERFACE 25 ATM Add/Delete Entry

 

Device Name:6E132-25

 

 

Flash Image Revision: XX.XX.XX

Slot Number: X

 

 

 

BOOTPROM Revision:XX.XX.XX

IF

VPI

VCI

AAL Type Encapsulation Type

BW (Mbps)

0

0

0

[ 5 ]

VC Mux 802.3 Bridged

1

Total Bandwidth On Interface: 155

Total Bandwidth Allocated: 125

 

 

 

ADD/MODIFY

EXIT

RETURN

 

 

 

 

 

 

 

Figure 3-19 The Add/Delete Entry Screen

3.20.1 Add/Delete Entry Screen Fields

IF (Modifiable)

This field represents the MIB-II interface on which the new PVC will be created. If multiple PVCs will be created on one MIB-II interface, the number of the desired interface should be entered in this field. If a new MIB-II interface will be used for the new PVC this field can be left at “0”. The HSIM-A6DP will automatically use the next available interface for this PVC.