Chapter 6: Troubleshooting
2.If the remote station is ready and the LNK LED is on, but no data passes through the port, one of the following two conditions may exist:
•Network management disabled the port.
•The port is segmented either because the collision detector was on for more than 110 ∝s or the SEHI detected more than 32 consecutive collisions on the attached segment. The affected port remains segmented until a good packet is transmitted/received without collisions.
If the LNK LED is still off, contact Cabletron Systems Technical Support.
6.2USING LANVIEW
The SEHI incorporates the Cabletron Systems LANVIEW status monitoring and diagnostics system. LANVIEW LEDs help diagnose problems such as power failure or cable fault. The SEHI uses the following LANVIEW LEDs:
•PWR, for power status
•CPU, for board status
•RCV (Receive), LNK (Link), and CLN (Collision) for Ethernet status.
Figure
SEHI User’s Guide |