Chapter 3: Local Management for T1 Service
3.3.1T1 Service Physical Configuration
Begin the T1 configuration by accessing the WAN Physical Configuration screen through Local Management (Figure
Proceed with the following steps:
1.Use the arrow keys to highlight the WPIM X field at the bottom of the screen. Press the SPACE bar to select the number of the WPIM to be configured, then press ENTER.
2.Use the arrow keys to highlight MgrType. Select PPP.
NOTE |
When changing from one protocol to another on a
3.Use the arrow keys to highlight Timeslot View. Press the SPACE bar to select New, then press ENTER. The cursor moves to Timeslot #1 of the Timeslot Configuration Table.
4.Insert an interface number (refer to NOTE below) into every timeslot as needed. Type the number, press ENTER, then use the arrow keys to highlight the next timeslot field. Exit this field by using the arrow keys. The cursor automatically moves to the T1 Line Coding field.
NOTE |
The value assigned to the timeslots is the interface being used for WAN communication. The next available interface is displayed on the WAN Physical Configuration screen in the Next IF field (seeFigure
The following four steps are based on information supplied by the service provider. Consult the service provider for the correct settings.
5.Use the arrow keys to highlight T1 Line Coding. Press the SPACE bar to select B8ZS or AMI, then press ENTER.
6.Use the arrow keys to highlight T1 Frame Type. Press the SPACE bar to select ESF or D4, then press ENTER.
|