Chapter 2: Setup and Installation

2.1.2Pre-Installation

To prepare the host platform for the WPIM-T1/DDS, proceed as follows:

1.Turn off and disconnect the host platform from the power source.

2.Mark all network cables attached to the host platform for ease of re-installation.

3.Disconnect all network cables attached to the host platform.

4.Refer to detailed instructions contained in the host platform’s user guide to remove the chassis cover. This procedure must be completed before installing the WPIM-T1/DDS.

2.1.3Installing the WPIM-T1/DDS

To install the WPIM-T1/DDS into the device, refer to Figure 2-1and complete the following steps:

When removing an existing WPIM, make sure to pull the

!module straight up to avoid damaging the connector.

CAUTION

1.Remove the blank faceplate from the appropriate WAN slot by removing the three WPIM screws that secure it to the standoffs.

2.Orient the WPIM-T1/DDS as shown in Figure 2-1.

3.Carefully insert the WPIM-T1/DDS connector into the WPIM connector pins on the device.

4.Press down firmly on the WPIM-T1/DDS until the pins slide all the way into the connector. Ensure that the WPIM-T1/DDS seats flush on the standoffs.

5.Secure the WPIM-T1/DDS to the three standoffs with the WPIM screws.

2-2

WPIM-T1/DDS User’s Guide

Page 20
Image 20
Cabletron Systems manual Pre-Installation, Installing the WPIM-T1/DDS