Chapter 3: Local Management for T1 Service

The line configuration information shown in Table 3-3must be supplied by the service provider.

Table 3-3 Telco Configuration Information

Configuration Information

Information Supplied by Service

Required by Customer

Provider

 

 

 

 

Line Coding

B8ZS or AMI

 

 

Frame Type

ESF or D4

 

 

Clock Source

Loop Timing or Local Timing

 

 

DS-0s (Timeslots)

Timeslots being used for each end of

 

the circuit

 

 

3.5.1Frame Relay Physical Configuration

Begin the WPIM-T1/DDS physical configuration by accessing the WAN Physical Configuration screen through Local Management (Figure 3-1). Proceed with the following steps:

1.Use the arrow keys to highlight the WPIM X field at the bottom of the screen. Press the SPACE bar to select the number of the WPIM to be configured, then press ENTER.

Use the arrow keys to highlight the MgrType field. Configure Protocol Manager Type as either FR PtoMP or FR PtoP. There are two settings for Frame Relay, Point to Point (FR PtoP) and Point to Multipoint (PtoMP). Frame Relay Point to Point has one Interface per DLCI assigned when DLCIs are created by the Service Provider. In Frame Relay Point to Multipoint, there is one interface to multiple DLCIs, and the DLCIs are dynamically learned. Backup can only be run on FR PtoP, not FR PtoMP.

NOTE

When changing from one protocol to another on a WPIM-T1/DDS that has been operational, save NONE as the protocol before changing to another protocol.

2.Use the arrow keys to highlight Timeslot View. Press the SPACE bar to select New, then press ENTER. The cursor moves to the first timeslot available in the Timeslot Configuration Table.

3-18

WPIM-T1/DDS User’s Guide

Page 42
Image 42
Cabletron Systems T1 manual Frame Relay Physical Configuration