Frame Relay Configuration

3.4.2T1 Interface Configuration

The WAN Interface Configuration screen is accessed through the WAN Physical Configuration screen. Access the WAN Interface Configuration screen by using the arrow keys to highlight the WAN INT CONFIG command and press ENTER. Refer back to Figure 3-4and proceed with the following steps to configure the WAN Interface.

1.Set the WAN connection Interface Number by typing the same number into the Interface Number field that was input into the timeslots in the WAN Physical Configuration screen, then press ENTER (refer to the Note on page 3-16).

2.Unless the user sets the Max Xmit Unit, the WPIM-T1/DDS automatically sets the Max Xmit Unit to 1526 (default) after the active protocol (PPP) is selected.

3.Make any changes to the available settings as desired.

4.Use the arrow keys to highlight the SAVE command, then press ENTER. The message “Save Done!” appears and Local Management saves the changes to memory.

The WAN configuration is complete. It takes up to 60 seconds for the WAN Interface to come out of standby and for communications to begin.

3.5FRAME RELAY CONFIGURATION

This section provides step-by-step instructions for configuring the WPIM-T1/DDS to use a T1 circuit in a Frame Relay environment. This example assumes the setup shown in Figure 3-8using two CSX400s, each with a WPIM-T1/DDS installed. Configurations may vary depending on the host platform.

SITE #1

Telco Cloud

24 Timeslots

SITE #2

24 Timeslots

1482_05

Figure 3-8 Frame Relay Configuration

WPIM-T1/DDS User’s Guide

3-17

Page 41
Image 41
Cabletron Systems T1 manual Frame Relay Configuration, Frame Relay Configuration