Chapter 2: Setup and Installation

2.4CONNECTING THE WAN CABLE TO THE WPIM-T1/DDS

Before connecting any cabling to the WPIM-T1/DDS, the WAN configuration must be complete. Refer to the previous section for information (Section 2.3.2) if the WAN configuration has not been completed.

DO NOT plug the WAN cable into the external WAN connection

!until you have properly completed the WAN setup in software. If

CAUTION

this cable is plugged in prematurely, before the host unit is

 

 

configured, the telephone company can disable the WAN line

 

for a period of time. The cable will be plugged in as a final step

 

once you run the QuickSET configuration, or the Local

 

Management configuration.

The RJ45 cable from the WPIM-T1/DDS must be plugged into the WAN connection wall jack (see Figure 2-3, below). The cables are not supplied with the WPIM-T1/DDS, but may be ordered separately from Cabletron Systems (cable part number 9372094 for T1, and part number 9360119 for DDS service). Refer to Appendix A for details.

WAN Connection Wall Jack

Host Platform

T1

DDS

WPIM

T1/DDS

connect

Figure 2-3 WAN Connection to the WPIM-T1/DDS

2-6

WPIM-T1/DDS User’s Guide