Carrier 33CS450-01 How to Set and Reset the Humidifier Run-Time Alert, Page, Carrier, Mode, Setup

Models: 33CS450-01

1 113
Download 113 pages 43.67 Kb
Page 92
Image 92
How to Set and Reset the Humidifier

Carrier

How to Set and Reset the Humidifier

Run-Time Alert

This counter keeps track of the number of days since the Service Humidify icon was last reset; this icon will appear after the number of days set in step #47 (below) has elapsed. Setting this counter to zero in step #47 will prevent the Service Humidify icon from ever appearing.

MODE

Press the MODE button. While holding

 

the MODE, press the PROGRAM

PROGRAM

button to enter Setup screens.

MODE

Press the MODE button repeatedly

until this setup screen appears.

 

Note: Press the MODE button momentarily to move through the setup screens. Press and hold the MODE button to move back- wards through the setup screens.

Days since the last reset

of the Service Humidify Days since the last reset 0 counter.

Press Reset the counter to 0 to

Service

remove the Service Humidify

 

icon from the display.

 

FAN

 

Setup I7

Humidify

Press the MODE button repeatedly

MODE

until this setup screen appears.

Adjust the number of days in increments of 10 before the Service Humidify icon appears.

0 = Off

(0 - 1990 days)

 

 

 

 

 

 

0

 

Setup

47

 

 

 

Service

 

Humidify

 

 

 

 

 

 

 

 

 

Press

PROGRAM

19

Press the PROGRAM button to leave the Setup screens. If no buttons are pressed, the display will leave the setup screens after 30 seconds.

The humidifier run-time alert does not take the place of any humidifier manufacturer’s recommended maintenance plan; it only serves as a helpful reminder.