Calibrating the Temperature and Humidity Sensors

Carrier

Calibrating the Temperature and Humidity Sensors

Under normal circumstances it will not be necessary to adjust the calibration of the temperature and humidity sensors. If calibration is required, please contact a trained HVAC technician to correctly perform the following procedure.

MODE

Place the thermostat in the OFF mode.

 

 

I2:00 Pm

72

OFF

Su

 

 

 

MODE

Press and hold the MODE button. While holding the MODE button, press and hold the FAN button for 5 seconds.

Am Program On Setup

 

I8:88 Pm StartStop

HI

SuMoTuWeThFrSa DeHumidify

Service Filter

 

88

Pan UV Light

 

COOL

AUTO

 

Outside

OFFON

 

Remote

UnoccupiedI88AUXHEAT

MODE

MODE

FANAll icons will appear on the display.

PRESS

THERMOSTAT SENSOR

Press the UP and DOWN buttons at the same time twice. The thermostat temperature will be displayed and may be calibrated using the UP or DOWN buttons.

TWICE

REMOTE SENSOR

Press the MODE button once. The remote sensor temperature will be displayed and may be calibrated using the UP or DOWN buttons. If a remote sensor is not installed, a temperature reading -127 degrees will appear.

HUMIDITY SENSOR

Press the MODE button once. The relative humidity at the thermostat will be displayed and may be calibrated using the UP or DOWN buttons.

123

LO

Override

88

FanOn

CALIBRATE

Remote

CALIBRATE

 

CALIBRATE

Place the thermostat in the OFF mode.I2:00 Pm 22

After calibration is complete, press the MODE button once to save your changes and return to normal operation.

Page 22.3