Calibrating the Temperature and Humidity Sensors
Under normal circumstances it will not be necessary to adjust the calibration of the temperature and humidity sensors. If calibration is required, please contact a trained HVAC technician to correctly perform the following procedure.
MODE
Place the thermostat in the OFF mode.
|
|
I2:00 Pm | 72 |
OFF | |
Su |
|
|
|
MODE
Press and hold the MODE button. While holding the MODE button, press and hold the FAN button for 5 seconds.
Am Program On Setup |
| |
I8:88 Pm StartStop | HI | |
SuMoTuWeThFrSa DeHumidify | ||
Service Filter |
| 88 |
Pan UV Light |
| COOL |
AUTO |
| Outside |
OFFON |
| Remote |
UnoccupiedI88AUXHEAT |
MODE
MODE
FANAll icons will appear on the display.
PRESS
THERMOSTAT SENSORPress the UP and DOWN buttons at the same time twice. The thermostat temperature will be displayed and may be calibrated using the UP or DOWN buttons.
TWICE
REMOTE SENSORPress the MODE button once. The remote sensor temperature will be displayed and may be calibrated using the UP or DOWN buttons. If a remote sensor is not installed, a temperature reading
Press the MODE button once. The relative humidity at the thermostat will be displayed and may be calibrated using the UP or DOWN buttons.
123 | LO |
Override | 88 |
FanOn |
CALIBRATE
Remote | CALIBRATE |
|
CALIBRATE
22
After calibration is complete, press the MODE button once to save your changes and return to normal operation.