LEGEND FOR FIG. 38 and 39

LEGEND FOR FIG. 38 and 39

AHA

Ð Adjustable Heat Anticipator

IFM

Ð Indoor (Evaporator)

TH

Ð Thermostat Heating

BKR W/AT Ð Breaks with Amp Turns

 

Fan Motor

TRAN Ð Transformer

C

Ð Contactor, Compressor

IFR

Ð Indoor (Evaporator)

 

Terminal (Marked)

CB

Ð Circuit Breaker

 

Fan Relay

 

CC

Ð Cooling Compensator

IP

Ð Internal Protector

 

 

CH

Ð Crankcase Heater

L

Ð Light

 

Terminal (Unmarked)

CLO

Ð Compressor Lockout

LOR

Ð Lockout Relay

 

 

CLS

Ð Compressor Lockout Switch

LPS

Ð Low-Pressure Switch

 

Terminal Block

COMP

Ð Compressor Motor

LS

Ð Limit Switch

 

 

 

CR

Ð Control Relay

MAT

Ð Mixed-Air Thermostat

 

Splice

CT

Ð Current Transformer

MGV Ð Main Gas Valve

 

DM

Ð Damper Motor

NEC

Ð National Electrical Code

 

Splice (Marked)

DU

Ð Dummy Terminal

OAT

Ð Outdoor-Air Thermostat

 

EQUIP

Ð Equipment

OFC

Ð Outdoor (Condenser)

 

 

FPT

Ð Freeze Protection

 

Fan Contactor

 

Splice (Field Supplied)

 

Thermostat

OFM Ð Outdoor (Condenser)

 

 

FU

Ð Fuse

PGV

Fan Motor

 

Factory Wiring

GND

Ð Ground

Ð Pilot Gas Valve

 

 

HPS

Ð High-Pressure Switch

PL

Ð Plug Assembly

 

Field Control Wiring

HR

Ð Heat Relay

PRI

Ð Primary

 

 

HV

Ð High Voltage

PS

Ð Pressure Switch

 

Field Power Wiring

I

Ð Ignitor

QT

Ð Quadruple Terminal

 

 

ICP

Ð Ignitor Control Pack

R

Ð Relay

 

Accessory or Optional Wiring

IDM

Ð Induced-Draft Motor

RS

Ð Rollout Switch

 

To Indicate Common Potential Only,

IDR

Ð Induced-Draft Relay

SN

Ð Sensor

 

IFC

Ð Indoor (Evaporator)

SW

Ð Switch

 

Not To Represent Wiring

 

Fan Contactor

TB

Ð Terminal Block

 

 

IFCB

Ð Indoor (Evaporator)

TC

Ð Thermostat Cooling

 

 

 

Fan Circuit Breaker

TDR

Ð Time Delay Relay

 

 

NOTES:

1.Compressor and fan motors thermally protected; 3-phase motors protected against primary single-phasing conditions.

2.If any of the original wire furnished must be replaced, it must be replaced with type 90 C wire or its equivalent.

3.Jumpers are omitted when unit is equipped with economizer.

4.Set thermostat heat anticipator(s):

UNIT

W1

W2

VOLTAGE

48HJD015

1.20

Ð

All

48HJD025, HJE015,

1.20

0.60

All

HJE017

 

 

 

5.CB must-trip amps are equal to or less than 140% full load amps.

6.Number(s) indicates the line location of used contacts. A bracket over (2) numbers signi®es a single-pole, double-throw contact. An underlined number signi®es a normally-closed contact. A plain (no line) number signi®es a normally-open contact.

7.The CLO locks out the compressor to prevent short cycling on com- pressor overload and safety devices. Before replacing CLO, check these devices.

27

Page 27
Image 27
Carrier 48HJ015-025 installation instructions LEGEND FOR and