Table 1 Ð Physical Data

UNIT SIZE 48

HJD015/HJE015

 

HJE017

 

HJD025

208/230, 460 V

 

575 V

 

 

 

 

 

 

 

 

OPERATING WT (lb)

 

 

 

 

 

 

 

Al/Al*

1640/1660

 

 

2010

 

2235

Unit Al/Cu*

1770/1790

 

 

2160

 

2385

Cu/Cu*

1840/1860

 

 

2250

 

2515

Economizer

110

 

 

 

110

 

110

Roof Curb²

200

 

 

200

 

200

COMPRESSOR

 

 

06D Semi-Hermetic

 

Number

1

 

 

 

2

 

2

Cylinders

6

 

 

 

4

 

6

REFRIGERANT TYPE

 

 

R-22

 

 

 

Charge (lb)

 

 

 

 

 

 

 

System 1

22.50

 

 

14.25

 

17.50

System 2

Ð

 

 

 

15.00

 

17.00

CONDENSER COIL

Copper Tubes, Aluminum or Copper Plate Fins

 

Rows

3

 

 

 

4

 

4

Fins/in.

15

 

 

 

15

 

15

Total Face Area (sq ft)

22.2

 

 

 

22.2

 

22.2

CONDENSER FAN

 

 

Propeller Type, Direct Drive

 

Nominal Cfm

10,500

 

 

10,500

 

14,200

Number...Diameter (in.)

3...22

 

 

3...22

 

2...30

Motor Hp (1075 Rpm)

1¤2

 

 

 

1¤2

 

1...1075

Watts Input (Total)

1090

 

 

1090

 

3400

EVAPORATOR COIL

Copper Tubes, Aluminum or Copper Plate Fins

 

Rows

2

 

 

 

3

 

4

Fins/in.

17

 

 

 

15

 

15

Total Face Area (sq ft)

17.9

 

 

 

17.9

 

17.9

EVAPORATOR FAN

Centrifugal, Adjustable Pitch Belt Drive

 

Quantity...Size (in.)

2...10 x 10

 

2...10 x 10

 

2...12 x 12

 

2...12 x12

Nominal Cfm

5000

 

5000

 

6000

 

8000

Fan Rpm Range

1194-1526

 

1201-1462

 

1238-1494

 

1323-1579

Maximum Allowable Rpm

1550

 

1550

 

1550

 

1550

Motor Pulley Pitch Diameter (in.)

3.4/4.4

 

4.3/5.3

 

5.4/6.6

 

5.8/7.0

Fan Pulley Pitch Diameter (in.)

5.2

 

6.4

 

7.9

 

7.9

Belt, Quantity...Type...Length (in.)

1...AX...42

 

1...B...45

 

1...BX...50

 

1...BX...51

Factory Speed Setting (Rpm)

1293

 

1279

 

1366

 

1451

Motor Hp (Service Factor)

3.7 (1.15)

 

3 (1.15)

 

5 (1.15)

 

10 (1.15)

Motor Frame Size

56H

 

56H

 

184T

 

215T

FURNACE SECTION

 

 

 

 

 

 

 

Rollout Switch Cutout Temp (F)**

190

 

 

 

190

 

190

Burner Ori®ce Diameter (in. ...drill size)

.113...33

 

 

.113...33

 

.113...33

Natural Gas

 

 

 

(1) .055...54/

 

 

 

 

 

Pilot Ori®ce Diameter (Quantity) in. ...drill size

 

 

(1) .055...54

 

(1) .055...54

(1) .055...54

 

 

 

Natural Gas

 

 

(1) .041...59

 

(1) .041...59

(1) .041...59

 

 

 

Thermostat Heat Anticipator Setting

 

 

 

 

 

 

 

 

 

 

 

 

Stage 1

1.2/1.2

 

 

1.2

 

1.2

Stage 2

Ð/0.6

 

 

 

0.6

 

0.6

Gas Valve Quantity

1/2

 

 

 

2

 

2

HIGH-PRESSURE SWITCH

 

 

 

 

 

 

 

Cutout (psig)

 

 

426

 

 

 

Reset (psig)

 

 

320

 

 

 

LOW-PRESSURE SWITCH

 

 

 

 

 

 

 

Cutout (psig)

 

 

7

 

 

 

Reset (psig)

 

 

22

 

 

 

AIR INLET SCREENS

 

 

Cleanable

 

 

 

Economizer, Quantity...Size (in.)

 

 

2...20 x 25 x 1

 

 

 

1...20 x 20 x 1

 

 

 

 

 

RETURN-AIR FILTERS (TYPE)

10% Efficient Ð 2-in. Throwaway Fiberglass

 

Quantity... Size (in.)

 

 

4...20 x 20 x 2

 

 

 

4...16 x 20 x 2

 

 

 

 

 

LEGEND

 

 

 

 

 

 

 

Al Ð Aluminum

 

 

 

 

 

 

 

Cu Ð Copper

 

 

 

 

 

 

 

*Evaporator coil ®n material/condenser coil ®n material.

 

 

 

 

 

 

 

²Weight of 14 in. roof curb.

 

 

 

 

 

 

 

**Rollout switch is manual reset.

 

 

 

 

 

 

 