Table 4 – Opening dimensions - In. (mm)

Table 4 – Opening dimensions - In. (mm)

 

 

 

 

 

 

FURNACE

 

PLENUM OPENING

FLOOR OPENING

CASING

APPLICATION

 

 

 

 

WIDTH

 

A

B

C

D

 

 

 

 

 

 

 

Upflow Applications on Combustible or Noncombustible Floor-

12--- 11/16

21--- 5/8

13--- 5/16

22--- 1/4

 

ing (KGASB subbase not required)

(322)

(549)

(338)

(565)

 

Downflow Applications on Noncombustible Flooring (KGASB

12--- 9/16

19

13--- 3/16

19--- 5/8

14–3/16

subbase not required)

(319)

(483)

(335)

(498)

Downflow applications on combustible flooring (KGASB sub-

11--- 13/16

19

13--- 7/16

20--- 5/8

(376)

base required)

(284)

(483)

(341)

(600)

 

 

Downflow Applications on Combustible Flooring with CNPV,

12--- 5/16

19

13--- 5/16

20

 

CNRV, CAR, or CAP Coil Assembly or KCAKC coil box

 

(319)

(483)

(338)

(508)

 

(KGASB subbase not required)

 

 

 

 

 

 

 

 

 

 

 

 

Upflow Applications on Combustible or Noncombustible Floor-

16

21--- 5/8

16--- 5/8

22--- 1/4

 

ing (KGASB subbase not required)

(406)

(549)

(422)

(565)

 

Downflow Applications on Noncombustible Flooring (KGASB

15--- 7/8

19

16--- 1/2

19--- 5/8

17–1/2

subbase not required)

(403)

(483)

(419)

(498)

Downflow applications on combustible flooring (KGASB sub-

15--- 1/8

19

16--- 3/4

20--- 5/8

(445)

base required)

(384)

(483)

(425)

(600)

 

 

Downflow Applications on Combustible Flooring with CNPV,

15--- 1/2

19

16--- 1/2

20

 

CNRV, CAR, or CAP Coil Assembly or KCAKC coil box

 

(394)

(483)

(419)

(508)

 

(KGASB subbase not required)

 

 

 

 

 

 

 

 

 

 

 

 

Upflow Applications on Combustible or Noncombustible Floor-

19--- 1/2

21--- 5/8

20--- 1/8

22--- 1/4

 

ing (KGASB subbase not required)

(495)

(549)

(511)

(565)

 

Downflow Applications on Noncombustible Flooring (KGASB

19--- 3/8

19

20

19--- 5/8

21

subbase not required)

(492)

(483)

(508)

(498)

Downflow applications on combustible flooring (KGASB sub-

18--- 5/8

19

20--- 1/4

20--- 5/8

(533)

base required)

(473)

(483)

(514)

(600)

 

 

Downflow Applications on Combustible Flooring with CNPV,

19

19

20

20

 

CNRV, CAR, or CAP Coil Assembly or KCAKC coil box

 

(483)

(483)

(508)

(508)

 

(KGASB subbase not required)

 

 

 

 

 

 

Upflow Applications on Combustible or Noncombustible Floor-

23

21--- 1/8

23--- 5/8

22--- 1/4

 

ing (KGASB subbase not required)

(584)

(537)

(600)

(565)

 

Downflow Applications on Noncombustible Flooring (KGASB

22--- 7/8

19

23--- 1/2

19--- 5/8

24--- 1/2

subbase not required)

(581)

(483)

(597)

(498)

Downflow applications on Combustible flooring (KGASB sub-

22--- 1/8

19

23--- 3/4

20--- 5/8

(622)

base required)

(562)

(483)

(603)

(600)

 

 

Downflow Applications on Combustible Flooring with CNPV,

22--- 1/2

19

23--- 1/2

20

 

CNRV, CAR, or CAP Coil Assembly or KCAKC coil box

 

(572)

(483)

(597)

(508)

 

(KGASB subbase not required)

 

 

 

 

 

58CT

UPFLOW DOWNFLOW HORIZONTAL

90û

 

90û

YES

YES

YES

 

120û

YES

120û

YES

120û

YES

MIN

 

MIN

 

MIN

 

NOT

NOT

NOT

RECOMMENDED

RECOMMENDED

RECOMMENDED

A02329